![Siemens SIMOTICS DC 1GH5 Operating And Installation Instructions Download Page 80](http://html.mh-extra.com/html/siemens/simotics-dc-1gh5/simotics-dc-1gh5_operating-and-installation-instructions_379012080.webp)
9.1.2
MTTR
Note
The operating conditions can vary greatly. For that reason, the following table only states
general intervals for inspections and service during fault-free operation.
Table 9-1
MTTR in fault-free operation
Measure
Interval
Time limit
Initial inspection
After 500 operating hours
After a half year at the
latest
Regreasing
After 1000 to 16 000 operating hours (depending on
bearings and operating mode)
After three years at
the latest
Cleaning
Dependent on local degree of pollution or when brush‐
es are replaced
Follow-up inspection 2,000 operating hours after the previous inspection
After a half year at the
latest
General inspection
Approximately every 16 000 operating hours
After two years at the
latest
9.1.3
Main inspection
The main inspection of the machine should be carried out after approximately 16000 operating
hours, but no later than after two years of operation.
DANGER
Rotating or live parts
Rotating or live parts are dangerous. Death, serious injury, or material damage can result if
the required covers are removed.
If no inspection windows are fitted and, as a result, the appropriate covers need to be removed
to allow inspection of the commutating performance, these covers may only be dismounted
by specially qualified personnel. This ensures that there is no contact with live or moving
parts. Wear safety goggles when working.
Checking the motor when in operation
● The relevant technical data are observed: power consumption, temperature of windings,
bearings, coolants, etc.
● There should be no oil, grease, or water leakages.
● The smooth running characteristics and motor running noise have not deteriorated.
● No impermissible brush sparking occurs in operation.
Maintenance
9.1 Inspection and maintenance
SIMOTICS DC 1GH5
80
Operating Instructions 02/2016
Summary of Contents for SIMOTICS DC 1GH5
Page 2: ...08 02 2016 10 31 V4 00 ...
Page 12: ...Introduction 1 1 About these instructions SIMOTICS DC 1GH5 12 Operating Instructions 02 2016 ...
Page 50: ...Assembling 5 3 Installing the machine SIMOTICS DC 1GH5 50 Operating Instructions 02 2016 ...
Page 76: ...Operation 8 9 Faults SIMOTICS DC 1GH5 76 Operating Instructions 02 2016 ...
Page 98: ...Maintenance 9 2 Repair SIMOTICS DC 1GH5 98 Operating Instructions 02 2016 ...
Page 110: ...Spare Parts 10 7 Speed sensor SIMOTICS DC 1GH5 110 Operating Instructions 02 2016 ...
Page 114: ...Service and Support SIMOTICS DC 1GH5 114 Operating Instructions 02 2016 ...
Page 118: ...Quality documents SIMOTICS DC 1GH5 118 Operating Instructions 02 2016 ...
Page 128: ...Index SIMOTICS DC 1GH5 128 Operating Instructions 02 2016 ...
Page 129: ......