Technical data
3 Technical
data
3.1.1 Video
Video inputs
BNC sockets
U
ss
=1V video, 75
, with plug-in jumpers and switchable
terminations
Video outputs
BNC sockets
U
ss
=1V video, 75
Video signal failure recognition
Vertical synchronisation pulse monitoring
Text overlay
Complete IBM character set,
internal synchronisation,
character display: white background, black frame
Field size:
12 text lines of 24 characters each
Character height:
18 screen lines
Cross-talk attenuation
56 dB at 5 MHz
Differential amplification
1%
Differential phase
0,6
Frequency response characteristic
-0.5 dB at 6 MHz
Switching point change-over time after
command signal reception at the video matrix
80 ms (typical), 200 ms (max.)
3.1.2 Control
Control computer
6 RISC-Controller
Interfaces for
Progr.-PC, IVM-NT, TELEMAT, SIPASS, LMS 3 x V.24 interfaces
Baud rate:
1200 – 19,200 bit/s
Connection:
3 x 9-pin Sub-D connectors
Keyboards
8 x TTY(20mA) interfaces with built-in electrical supply for 8
keyboards, (supply max. 800mA total)
Cable length:
up to 2 km, wire diameter 0.8 mm
Baud rate:
1200 – 9600 bit/s
Connection:
8 x RJ12 sockets
PTZ control (CDC)
16 x CDC(20mA) interfaces
Cable length:
up to 2 km, wire diameter 0.8 mm
Baud rate:
1200 – 9600 bit/s
Control of Telemetrie devices
4 x RS422/RS485-Ports;
Protocols:
CCDA, SCU, SIVIS, PELCO-D
Connection:
4 x RJ11-Buchse / Port
Sensor groups
Alarm sensors, alarm contacts
32 x alarm inputs for detection groups
Cable length:
up to 10 m
Connection:
2 x 37-pin Sub-D socket