Set-up
Fig. 20
Second message following a system start (if keyboard 1 is connected)
T.1 =OK
This line means that keyboard 1 is connected.
2400 19.2k 19.2k 19.2k
This line indicates the data exchange rates for COM1 to COM4. In this example,
keyboard 1 communicates with the SIMATRIX NEO V2 at 2400 Baud. COM2,
COM3 and COM4 are set to 19,200 Baud.
7.2
Installing the control software and setting device parameters
1.
Install the control software
Use the
CD supplied with the unit to install the
control program. Then start up
the control program.
2.
If the SIMATRIX NEO V2 is coupled via LAN and the IP address is not known,
first use the diagnosis tool to find the SIMATRIX NEO V2 in the network, read
out/assign the IP address, and then set the parameters via the network.
3.
Set the system time in the SIMATRIX NEO
You must start the system's real-time clock if it is not active
(No Time!
appears in the display),as otherwise a number of important system functions,
such as alarm sequencing, will not be available.
Control software:
System real-time clock
and OSD clocks
button
4.
Setting basic parameters
Basic parameters
button
Camera and monitor settings
5.
Setting basic alarm parameters
Basic alarm
parameters
button
Alarm sensor settings
6.
Setting camera labels
Camera texts button
7.
Test cameras, monitors and keyboards
Remote control and message receive button
8.
Alarm sensor to camera allocation
Alarm lines and camera groups button
9.
Further programming
If applicable, enter further parameters in order to tailor the function of the