4.7 Chemical resistance of the readers and transponders
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
75
Substance
Test conditions
Evaluation
Concentration [%] Temperature [°C]
Lactic acid, w.
50 %
20 ℃
++
10 %
20 ℃
+++
10 %
60 ℃
++
Sodium carbonate, w. (soda)
c. s.
60 ℃
++++
Sodium chloride, w.
c. s.
60 ℃
++++
Sodium hydroxide
-
60
℃
++++
Nickel salts, w.
c. s.
60 ℃
++++
Nitrobenzene
-
20 ℃
+++
-
60 ℃
++
Phosphoric acid
10 %
20 ℃
+
Propane
-
60 ℃
++++
Mercury
-
60 ℃
++++
Nitric acid
10 %
20 ℃
+
Hydrochloric acid
10 %
20 ℃
+
Sulfur dioxide
low
60 ℃
++++
Sulfuric acid
25 %
20 ℃
++
10 %
20 ℃
+++
Hydrogen sulfide
low
60 ℃
++++
Carbon tetrachloride
-
60 ℃
++++
Toluene
-
20 ℃
++++
-
60 ℃
+++
Detergent
high
60 ℃
++++
Plasticizer
-
60 ℃
++++
Explanation of the rating
++++
Resistant
+++
Practically resistant
++
Conditionally resistant
+
Less resistant
○
Not resistant
w.
Water solution
c. s.
Cold saturated