![Siemens SIMATIC RF640A System Manual Download Page 343](http://html.mh-extra.com/html/siemens/simatic-rf640a/simatic-rf640a_system-manual_374419343.webp)
Transponder
7.1 Overview
SIMATIC RF600
System Manual, 11/2018, J31069-D0171-U001-A21-7618
343
Table 7- 4
Read range of the transponders II (all ranges in meters [m])
SIMATIC RF642L
1)
SIMATIC RF690L
SIMATIC RF610T
SIMATIC RF620T
2)
SIMATIC RF615R
with internal antenna
0.8
0.2
0.8
1.0
with RF615A
0.2
0.1
0.3
1.0
with RF620A
0.4
0.1
0.4
1.2
with RF640A
1.2
0.1
1.2
4.0
with RF642A
2.0
0.3
3.0
4.0
with RF650A
0.8
0.1
1.2
3.5
with RF660A
1.8
0.3
3.0
4.0
with RF680A
1.0
0.1
1.4
4.0
SIMATIC RF650R
with RF615A
0.4
0.2
0.9
1.8
with RF620A
0.4
0.2
0.9
1.8
with RF640A
1.2
2.5
2.5
5.0
with RF642A
2.0
2.0
4.5
7.0
with RF650A
1.2
3.0
2.0
4.0
with RF660A
1.6
1.4
3.5
6.0
with RF680A
1.2
0.9
2.0
4.0
SIMATIC RF680R
with RF615A
0.5
0.2
1.2
2.5
with RF620A
0.5
0.3
1.4
2.5
with RF640A
1.4
3.5
3.0
6.0
with RF642A
2.0
2.0
4.5
7.0
with RF650A
1.6
3.5
3.0
5.0
with RF660A
1.6
1.4
3.5
6.0
with RF680A
1.6
1.4
3.0
6.0
SIMATIC RF685R
with internal antenna
2.0
3.0
5.0
7.0
with RF615A
0.5
0.2
1.2
2.5
with RF620A
0.5
0.3
1.4
2.5
with RF640A
1.4
3.5
3.0
6.0
with RF642A
2.0
2.0
4.5
7.0
with RF650A
1.6
3.5
3.0
5.0
with RF660A
1.6
1.4
3.5
6.0
with RF680A
1.6
1.4
3.0
6.0
1)
Mounting on metal. Mounting surface with a minimum diameter of 150 mm.
2)
Mounting on a non-metallic surface. Mounting on metal is only permitted in combination with a spacer.