![Siemens SIMATIC RF640A System Manual Download Page 436](http://html.mh-extra.com/html/siemens/simatic-rf640a/simatic-rf640a_system-manual_374419436.webp)
Transponder
7.14 SIMATIC RF680T
SIMATIC RF600
436
System Manual, 11/2018, J31069-D0171-U001-A21-7618
7.14.4
Technical specifications
Table 7- 56 Technical specifications of the transponder SIMATIC RF680T
6GT2810-2HG80
Product type designation
SIMATIC RF680T
Radio frequencies
Operating frequency
•
ETSI
•
865 to 868 MHz
•
FCC
•
902 ... 928 MHz
1)
Memory
Chip (manufacturer/type)
NXP / G2XM
Memory type
EEPROM
Memory configuration
•
EPC
•
12 ... 30 bytes / 96 ... 240 bits
•
User memory
•
64 bytes / 512 bits
•
TID
•
8 bytes / 64 bits
•
Reserved (passwords)
•
8 bytes / 64 bits
Number of write cycles (< 40 °C)
> 10
14
Number of read cycles (< 40 °C)
> 10
5
Data retention time (< 40 °C)
10 years
Electrical data
Range
≤ 5 m
2)
Protocol
ISO 18000-63
Transmission speed
≤ 320 kbps
Polarization
Linear
Mechanical specifications
Material
PPS
Silicone-free
Yes
Color
Black
Printing
No