![Siemens SIMATIC RF640A System Manual Download Page 112](http://html.mh-extra.com/html/siemens/simatic-rf640a/simatic-rf640a_system-manual_374419112.webp)
Readers
5.2 SIMATIC RF615R
SIMATIC RF600
112
System Manual, 11/2018, J31069-D0171-U001-A21-7618
5.2.5
Technical specifications
Table 5- 10 Technical specifications of the RF615R reader
6GT2811-6CC10-xAA0
Product type designation
SIMATIC RF615R
Radio frequencies
Operating frequency
•
ETSI
•
865 to 868 MHz
•
FCC
•
902 to 928 MHz
•
CMIIT
•
920 to 925 MHz
Transmit power
1)
•
ETSI
•
3 ... 400 mW
•
FCC
•
3 ... 400 mW
•
CMIIT
•
3 ... 400 mW
Maximum radiated power per antenna
•
ETSI
•
1000 mW ERP
•
FCC
•
1400 mW EIRP
•
CMIIT
•
1000 mW ERP
Electrical data
Range (internal antenna)
•
ETSI
•
≤ 1
m
•
FCC
•
≤ 1
m
•
CMIIT
•
≤ 1
m
Protocol
ISO 18000-62/-63
Transmission speed
≤ 300 kbps
Frequency accuracy
≤ ±10 ppm
Channel spacing
•
ETSI
•
600 kHz
•
FCC
•
500 kHz
•
CMIIT
•
250 kHz
Modulation methods
ASK: DSB modulation & PR-ASK modulation
encoding, Manchester or Pulse Interval (PIE)
Multitag capability
Yes