RF600 system planning
4.8 Chemical resistance of the readers and transponders
SIMATIC RF600
System Manual, 06/2019, J31069-D0171-U001-A22-7618
85
Substance
Test conditions
Evaluation
Concentration [%] Temperature [°C]
n(n)
-
20
℃
++++
-
60
℃
+++
Calcium chloride, w.
-
20
℃
++++
-
60
℃
+++
Calcium nitrate, w.
c. s.
20
℃
++++
c. s.
60
℃
+++
Chlorine
-
20
℃
○
Chrome baths, tech.
-
20
℃
○
Iron salts, w.
c. s.
60
℃
++++
Acetic acid, w.
50 %
20
℃
○
Ethyl alcohol, w., undenaturated
95 %
20
℃
++++
95 %
60
℃
+++
50 %
60
℃
++++
Formaldehyde, w.
30 %
20
℃
+++
10 %
20
℃
++++
10 %
60
℃
+++
FORMALIN
-
20
℃
+++
Glycerine
-
60
℃
++++
Isopropanol
-
20
℃
++++
-
60
℃
+++
Potassium hydroxide, w.
50 %
60
℃
++++
LYSOL
-
20
℃
++
Magnesium salts, w.
c. s.
60
℃
++++
Methyl alcohol, w.
50 %
60
℃
++++
Lactic acid, w.
50 %
20
℃
++
10 %
20
℃
+++
10 %
60
℃
++
Sodium carbonate, w. (soda)
c. s.
60
℃
++++
Sodium chloride, w.
c. s.
60
℃
++++
Sodium hydroxide
-
60
℃
++++
Nickel salts, w.
c. s.
60
℃
++++
Nitrobenzene
-
20
℃
+++
-
60
℃
++
Phosphoric acid
10 %
20
℃
+
Propane
-
60
℃
++++
Mercury
-
60
℃
++++
Nitric acid
10 %
20
℃
+
Hydrochloric acid
10 %
20
℃
+
Sulfur dioxide
low
60
℃
++++
Sulfuric acid
25 %
20
℃
++
10 %
20
℃
+++