System diagnostics
9.1 Diagnostics via the LED displays of the reader
SIMATIC RF600
468
System Manual, 06/2019, J31069-D0171-U001-A22-7618
①
LED status display (ST1 - ST9) - RF680R/RF685R only
②
LED operating display
•
RUN/STOP (R/S)
Shows whether the reader is ready for operation.
•
ERROR (ER)
Indicates whether an error has occurred.
•
MAINTENANCE (MAINT)
- only with
RF610R/RF615R/RF680R/
RF685R
Shows whether the reader needs maintenance.
•
POWER (PWR)
Shows whether the reader is supplied with power.
•
PRESENCE (PRE)
- only with
RF610R/RF615R/RF650R
Among other things, indicates whether or not there are multi-
ple transponders in the antenna field. With the
RF680R/RF685R readers, this is indicated by the status
display.
•
LINK 1 (LK1)
Indicates that there is a connection via Ethernet interface "1".
•
RECEIVE/TRANSMIT 1
(R/T1)
Indicates that data is being sent and/or received via Ethernet
interface "1".
•
LINK 2 (LK2)
- only with
RF680R/RF685R
Indicates that there is a connection via Ethernet interface "2".
•
RECEIVE/TRANSMIT 2
(R/T2)
- only with
RF680R/RF685R
Indicates that data is being sent and/or received via Ethernet
interface "2".
Figure 9-1
LED displays of the RF61xR, RF650R and RF68xR reader