Transponder
7.7 SIMATIC RF620T
SIMATIC RF600
System Manual, 06/2019, J31069-D0171-U001-A22-7618
403
6GT2810-2HC81
Permitted ambient conditions
Ambient temperature
•
In operation, during write/read access
•
-25 ... +85 °C
•
In operation, outside write/read access
•
-40 ... +85 °C
•
During transportation and storage
•
-40 … +80 °C
Distance from metal
≥
12 mm (with spacer)
Not suitable for mounting directly on metal
Degree of protection
IP67
Resistance to mechanical stress
Torsion and bending stress is not permitted
Shock resistant to EN 60068-2-27
100 g
2)
Vibration to EN 60068-2-6
50 g
2)
Design, dimensions and weight
Dimensions (L x W x D)
•
Transponder
•
127 × 38 × 6 mm
•
Spacer
•
157 × 39 × 12 mm
Weight
•
Transponder
•
18 g
•
Spacer
•
22 g
Type of mounting
2 x M4 screws
≤
1.2 Nm
1)
The information relates to the maximum read range. You will find more information on
ranges in the section "Minimum distances and maximum ranges (Page 55)".
2)
The values for shock and vibration are maximum values and must not be applied
continuously.