Modules
4.2 Installing/Removing Line Modules
Once a line module is removed, all the features associated with the module are hid-
den or disabled in RUGGEDCOM RSG2488F.
NOTICE
Only one Precision Time Protocol (PTP) line module is supported per chassis.
CAUTION
Contamination hazard – risk of equipment damage
Prevent the ingress of water, dirts and other debris that may lead to premature
equipment failure. Always make sure slots are not left empty and open ports are
protected with plugs or covers.
Removing a Module
To remove a line module, do the following:
1. Make sure power to the device has been disconnected and wait approximately
two minutes for any remaining energy to dissipate.
2. [Optional] If the device is installed in a rack, remove it from the rack.
3. Loosen the screws that secure the module.
4. Pull the module from the chassis to disconnect it.
3
1
2
1
Module
2
Chassis
3
Screw
Figure 4.2
Removing a Module
5. Install a new module or a blank module (to prevent the ingress of dust and dirt).
6. [Optional] If necessary, install the device in the rack.
32
RUGGEDCOM RSG2488F
Installation Manual, 11/2019, C79000-G8976-1351-05