Certification
6.2 EMC and Environmental Type Tests
temporary communication loss, while Class 2 requires error-free and interrupted
communications.
Description
Test Levels
Enclosure Contact
± 8 kV
ESD
Enclosure Air
± 15 kV
Radiated RFI
Enclosure Ports
35 V/m
Signal Ports
± 2 kV @ 2.5 kHz
DC Power Ports
± 1.5 kV
Fast Transient
Earth Ground Ports
± 2 kV
Signal Ports
2.2 kV Common Mode @ 1 MHz
Oscillatory
DC Power Ports
2.2 kV Common and
Differential Mode @ 1 MHz
Signal Ports
5 kV (Failsafe Relay)
HV Impulse
DC Power Ports
5 kV
Signal Ports
2 kV (Failsafe Relay)
Dielectric Strength
DC Power Ports
1.5 kV
Environmental Type Tests
Test
Description
Test Levels
Severity Levels
IEC 60068-2-1
Cold Temperature
Test Ad
-40 °C (-40
°F), 16 Hours
IEC 60068-2-2
Dry Heat
Test Bd
85 °C (185
°F), 16 Hours
IEC 60255-21-1
Vibration
2g @ 10-150 Hz
Class 2
IEC 60255-21-2
Shock
30g @ 11 ms
Class 2
RUGGEDCOM RS900GPF
Installation Manual, 01/2021, C79000-G8976-1353-05
35