background image

 

Documentation guide 

 

PDC100(F) 
Equipment Manual, 03/2021, A5E50502703-AA 

9

 

"mySupport" - CAx data 

In the CAx data area of "mySupport", you can access the latest product data for your CAx or 

CAe system. 
You configure your own download package with a few clicks. 
In doing so you can select: 

 

Product images, 2D dimension drawings, 3D models, internal circuit diagrams, EPLAN 

macro files 

 

Manuals, characteristics, operating manuals, certificates 

 

Product master data 

You can find "mySupport" - CAx data on the Internet 

(

https://support.industry.siemens.com/my/ww/en/CAxOnline

)

Application examples 

The application examples support you with various tools and examples for solving your 

automation tasks. Solutions are shown in interplay with multiple components in the system - 

separated from the focus on individual products. 
You will find the application examples on the Internet 

(

https://support.industry.siemens.com/sc/ww/en/sc/2054

)

TIA Selection Tool 

With the TIA Selection Tool, you can select, configure and order devices for Totally Integrated 

Automation (TIA). 

This tool is the successor of the SIMATIC Selection Tool and combines the known 

configurators for automation technology into one tool. 

An integral component of the TIA Selection Tool is the calculation tool for the design and 

component selection of the SIMATIC MICRO-DRIVE drive system. 
With the TIA Selection Tool, you can generate a complete order list from your product 

selection or product configuration. 
You can find the TIA Selection Tool on the Internet 

(

https://new.siemens.com/global/en/product-services/automation/topics/tia/tia-selection-

tool.html

)

Summary of Contents for SIMATIC MICRO-DRIVE

Page 1: ......

Page 2: ...100 F Equipment Manual 03 2021 A5E50502703 AA Preface Documentation guide 1 Product overview 2 Connecting 3 Alarms diagnostics error messages and system events 4 Technical specifications 5 Response times A Dimension drawing B ...

Page 3: ...ly by personnel qualified for the specific task in accordance with the relevant documentation in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens prod...

Page 4: ...de in this manual for the PDC100 drive controller also apply to the fail safe variant PDC100F Any differences are noted at the respective location The currents specified in this document with unit A correspond to the torque generating current Due to internal scaling this value accurately corresponds to the peak value of the alternating change To distinguish the effective values are marked with Aef...

Page 5: ...se visit https www siemens com industrialsecurity Siemens products and solutions undergo continuous development to make them more secure Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used Use of product versions that are no longer supported and failure to apply the latest updates may increase customers exposure t...

Page 6: ...log and order system of Siemens AG for automation and drive solutions on the basis of Totally Integrated Automation TIA and Totally Integrated Power TIP You can find catalogs for all automation and drive products on the Internet https mall industry siemens com and in the Information and Download Center ...

Page 7: ... capability of the power unit 18 3 Connecting 19 3 1 Terminal assignment 19 3 2 Schematic circuit diagram 22 3 3 Connecting the supply voltages 23 3 4 Connecting the motor 26 3 5 Connecting an external braking resistor 28 4 Alarms diagnostics error messages and system events 30 4 1 Status and error display 30 5 Technical specifications 32 5 1 Technical specifications 32 5 2 Drive controller derati...

Page 8: ...you in the configuration and programming Device information The manual contains a compact description of the device specific information such as properties interfaces wiring diagrams display and operator controls and technical specifications General information The function manuals contain detailed descriptions on general topics regarding the MICRO DRIVE servo drive system and SIMATIC S7 1500 auto...

Page 9: ...dustry siemens com website The Update to the S7 1200 System Manual https support industry siemens com cs ww en view 109743003 contains updates to the system manual SIMATIC S7 1200 Programmable Controller that occurred after its publication mySupport With mySupport your personal workspace you make the best out of your Industry Online Support In mySupport you can save filters favorites and tags requ...

Page 10: ... in interplay with multiple components in the system separated from the focus on individual products You will find the application examples on the Internet https support industry siemens com sc ww en sc 2054 TIA Selection Tool With the TIA Selection Tool you can select configure and order devices for Totally Integrated Automation TIA This tool is the successor of the SIMATIC Selection Tool and com...

Page 11: ...ng of the PROFINET name station name to a device Resetting of devices to factory settings resetting interface parameters Downloading of a firmware update to a device You can find the SIMATIC Automation Tool on the Internet https support industry siemens com cs ww en view 98161300 PRONETA SIEMENS PRONETA PROFINET network analysis allows you to analyze the plant network during commissioning PRONETA ...

Page 12: ...mic positioning tasks in production and manufacturing and in innovative application areas Examples of applications Packaging machines Automatic assembly machines Metal forming machines Printing and labeling machines Winders unwinders e g in the textile packing and printing industries and in electronics manufacturing Driving of shuttles for storage and retrieval machines and storage rack systems Au...

Page 13: ...anual 03 2021 A5E50502703 AA 2 2 Properties Article number Drive controller PDC100 6BK1 630 1AA10 0AA0 Drive controller PDC100F 6BK1 630 2AA10 0AA0 View of the device The figure below shows the PDC100 drive controller Figure 2 1 Product image of the PDC100 ...

Page 14: ...t overview 2 2 Properties PDC100 F Equipment Manual 03 2021 A5E50502703 AA 13 The fail safe variant PDC100F has yellow enclosure markings as well as yellow plug in connectors Figure 2 2 View of PDC100 PDC100F ...

Page 15: ...A or 1 56 Aeff Maximum 3 3 A or 2 33 Aeff Output phase current for a DC motor Horizontal vertical installation Nominal 2 2 A Maximum 3 3 A Typical power output with 48 V supply Horizontal vertical installation Nominal 100 W Maximum 150 W Braking resistor internal The PDC100 F drive controllers have an internal braking resistor with 30 J min to absorb the regenerative energy of the motor To use the...

Page 16: ...rolling and evaluating the safe ty functions of the drive controller System Manual SIMATIC MICRO DRIVE drive controller PDC https support industry siemens com c s ww en view 109774126 STO Safe Torque Off Stop function for safe torque shutdown according to stop category 0 according to EN 60204 1 SS1 Safe Stop 1 Stop function according to Stop Catego ry 1 according to EN 60204 1 time monitored SSM S...

Page 17: ... link not replaceable by user Fusing on installation side necessary for through wiring Power unit 4L 24 to 48 V DC 18 5 to 50 4 V DC1 18 5 to 50 4 V DC1 Max 60 V Two pole miniature circuit breaker 1 When energy recovery is activated a supply voltage above 50 4 V DC maximum value 56 6 V is also permitted Use a suitable bi directional supply to ensure that the voltage at 4L never exceeds 60 V DC dur...

Page 18: ...it breaker has to be installed between the power supply and PDC and not an operational switch If 4L is switched on via a suitable miniature circuit breaker the following characteristic values result Peak current 150 A Half value stream width 300 μs NOTICE The 4L input has no switch on current limitation Do not connect the terminals while live This must also be observed for any upstream switching d...

Page 19: ...emens com cs ww en view 109774126 2 4 Calculating the overload capability of the power unit The following table shows the relationship between overload and recovery of the power unit Calculation Table 2 2 Relationship between overload and recovery of the power unit PDC100 F Rated power unit current r0208 2 2 A or 1 56 Aeff Peak power unit current r0209 3 3 A or 2 33 Aeff Duration of overload with ...

Page 20: ... PDC X5060 Hardware STO X5060 SSI absolute encoder X5060 Motor phases X5050 External braking resistor X5050 Power supply of power unit X5050 Connection for grounding strap of the functional ground covered access from below PROFINET Port 1 X2050 and Port 2 X2060 covered access from below Reference potential of encoder Hall sensor supply X4050 Incremental encoder X4050 Hall sensor X4050 Wiring duct ...

Page 21: ...proven product partners of Siemens This allows you to optimally combine suitable products from proven product partners for your individual application You can find more information about the Siemens Product Partner Program on the Internet https new siemens com global en company topic areas partners product partners industry html Interfaces cable lengths and cable types The following cable lengths ...

Page 22: ... in one plug in cable 10 m Shielded in All in one plug in cable X5060 Logic supply PDC 1L 1M 20 m 2 m unshielded 2 m shielded Solid and stranded sup ply cable AWG 20 to 16 or 0 5 mm2 to 1 5 mm2 For through wiring for maximum permissible terminal currents use AWG 16 or 1 5 mm2 Safe Torque Off 20 m 2 m unshielded 2 m shielded SSI interface 20 m Shielded one twisted pair per signal pair Solid and str...

Page 23: ... 24 V DC Infeed of supply voltage for logic unit Supply for digital inputs outputs X5050 24 48 V DC Infeed of supply voltage for power unit Supply for logic unit PN P1 X2050 PROFINET interface Port 1 EMC filter current limitation PN P2 X2060 PROFINET interface Port 2 X5060 SSI encoder connection xL Supply voltage X5060 Hardware STO input xM Ground Microcontroller unit consisting of drive controlle...

Page 24: ... 2L and Pins 1 2 2M of interface X4060 are electrically connected to one another If you connect the supply voltage to Pin 3 2L and Pin 1 2M you can use terminals 4 2L and 2 2M to loop through the potential to Pins 3 1L and 1 1M of interface X5060 You connect the 24 V DC to 48 V DC supply voltage for the power unit to connector X5050 4L and 4M Requirements Only wire the connection plug when the sup...

Page 25: ...ent Interface X5060 for supply voltage of logic supply of PDC Pin Designation Function Pin Designation Function 1 1M Reference potential of logic supply of PDC 2 1M Reference potential of logic supply of PDC 3 1L Logic supply of PDC 4 1L Logic supply of PDC The logic supply voltages 1L 2L with associated ground potentials 1M 2M are electrically isolated from one another Connection of supply voltag...

Page 26: ...of conductors stranded without end sleeve unprocessed To connect a wire without end sleeve follow these steps 1 Strip 8 to 11 mm of insulation from the wires 2 Press the spring release with the screwdriver and insert the wire into the spring loaded terminal as far as it will go 3 Let go of the spring release with the screwdriver 4 Push the wired connection plug into the socket of the PDC 5 After c...

Page 27: ...om global en company topic areas partners product partners industry html Connections for motor phases The figure below shows the connection of the motor phases to interface X5050 DC motor 4U 4V 4W Motor phases EC motor 4L Power supply of power unit 4M Reference potential of power supply of power unit Figure 3 4 Connection of motor phases of DC motors and EC motors Note A DC motor must be connected...

Page 28: ...n 1 4U Motor phase U or for DC motor for positive direction of rotation 2 4 V Motor phase V or for DC motor for positive direction of rotation 3 4W Motor phase W 6 4L Power supply of power unit 7 4M Reference potential of power supply of power unit Reference Note the detailed information on the topic Connecting in the System Manual SIMATIC MICRO DRIVE Drive controller PDC https support industry si...

Page 29: ...ion housing temperature fuse The externally connected braking resistor cannot drop below a value of 2 25 ohms including all tolerances Note To enable sufficient braking power in all dynamic operating states a resistance value 8 ohms is recommended The figure below shows the connection of an external braking resistor to interface X5050 and X4060 Basic insulation 4R 4R Connection for external brakin...

Page 30: ...signation Function Interface X5050 1 4R Connection of external braking resistor 2 4R Interface X4060 example 4 2L For example interconnected with external temperature sensor 6 2DI3 Reference Note the detailed information on connection of an external braking resistor in the System Manual SIMATIC MICRO DRIVE Drive controller PDC https support industry siemens com cs ww en view 109774126 You can also...

Page 31: ... the LED flashes red there is an operating fault The SAFE LED indicates the status of the Safety Integrated functions The LEDs assume different statuses during startup The displays of the LEDs operate independent of one except during firmware update The figure below shows the various LED displays on the PDC Diagnostic LEDs for the drive controller RDY ERR Drive status SAFE Safety function status D...

Page 32: ...ervice behind the lower front cover P1 P2 Status information of PROFINET port MRES Service function status Figure 4 1 LED displays You can find detailed information and descriptions for the individual fault and alarm messages and the meanings of the LEDs for the status of the drive controller in the System Manual SIMATIC MICRO DRIVE Drive controller PDC https support industry siemens com cs ww en ...

Page 33: ...otor controller HW functional status FS01 Product description Control of DC and EC motors Mean time between failures MTBF 100 000 h Product function Isochronous mode Yes Four quadrant operation Yes Speed control with encoder Yes Speed control without encoder No Safety Functions Yes STO Yes STO SS1 SLT SLS SSM Protection function Undervoltage protection Yes Overvoltage protection Yes Overload prote...

Page 34: ...4 V DC Input characteristic according to IEC 61131 Permissible DC leakage current 0 signal to 2 mA Digital outputs Type of digital output Source output PNP current sourcing Number of digital outputs 2 Number of safety outputs 0 Encoder Connectable encoders Incremental encoder symmetrical Yes Up to 200 kHz Incremental encoder asymmetrical Yes Absolute encoder SSI Yes 350 kHz Interfaces Number of in...

Page 35: ... 5 g Vibration resistance during storage acc to IEC 60068 2 6 5 9 Hz 3 5 mm 9 500 Hz 1 g Shock testing Shock resistance during operation acc to IEC 60068 2 27 15 g 11 ms for wall mounting 10 g 30 ms 25 g 6 ms Cables Cable length for motor shielded max 10 m Dimensions Width 50 mm Height 125 mm 136 mm with protective collar for PN connector Depth 120 mm Weights Weight approx 350 g Other Brake design...

Page 36: ...nction of the installation altitude For all permissible mounting types starting from an installation altitude of 1000 m a derating of 10 current per additional 1000 m elevation gain applies In this case the motor current and the output current of the digital outputs must be reduced All other functions do not have to be reduced up to the maximum installation altitude The figure below shows the maxi...

Page 37: ...s Also note the permissible coincidence factors of the inputs outputs All outputs DQ may be operated simultaneously up to 60 C No deratings with respect to ampacity exist as a function of ambient temperature All inputs DI may be operated simultaneously up to 60 C No deratings with respect to ampacity exist as a function of ambient temperature ...

Page 38: ...detection of an input signal and the change of a linked output signal You will find the response times of the SIMATIC MICRO DRIVE drive system on the Internet https support industry siemens com cs ww en view 109777254 The response times of the drive enter into the calculation of the response time of the F system ...

Page 39: ... account the dimensions for installation in cabinets control rooms etc Dimension drawings of the SIMATIC MICRO DRIVE PDC100 F The PDC100 and PDC100F variants have an identical housing Figure B 1 Dimension drawings of the PDC100 front and side view as examples depending on mounting rail type used Dimension drawings of the shield bracket Figure B 2 Dimension drawing of shield bracket 50 mm for PDC10...