Appendix
A.4 Retrofitting instructions
SIMATIC IPC647C
Operating Instructions, 12/2010, A5E02669337-02
219
A.4
Retrofitting instructions
A.4.1
Configurations
Temperature range 5 °C to 50 °C
The maximum permissible power loss of expansion modules is 30 W. Distribution over the
slots:
●
25 W maximum for the PEG slot
●
25 W maximum for the upper module in slot 2
●
10 W maximum for the lower module in slot 3
Maximum permitted configuration
HDD / SSD
HDD / SSD
Slimline DVD RW / CF card
Figure A-1
Approved configuration versions for the temperature range 5 °C to 50 °C
Slimline DVD RW can be installed, but may only be operated as described below.
Note
The HDDs installed in the removable rack may not be exposed to vibratory loads during
operation and only to limited shock loads (see specifications).