Maintaining and repairing the device
6.3 Replacing the backup battery
SIMATIC IPC520A
44
Operating Instructions, 11/2021, A5E51366325-AA
UL approval of the device only applies when the UL-approved components are used according
to their "Conditions of Acceptability".
We are not liable for functional limitations caused by using third-party devices or
components.
6.3
Replacing the backup battery
Prior to replacement
WARNING
Risk of explosion and release of harmful substances
An explosion or fire HAZARD could occur through fitting a battery of the wrong type.
Improper handling of lithium batteries also can result in an explosion of the batteries.
Explosion of the batteries and the released pollutants can cause severe physical injury. Aged
batteries jeopardize the function of the device.
Note the following when handling lithium batteries:
•
Replace the battery every 3 years.
•
Replace the lithium battery only with the type recommended by the manufacturer. The
new lithium battery must be certificated by UL and meet the following requirements:
–
Type: CR2032W
–
Rated voltage: 3 V DC
–
Max abnormal charging current: 10 mA
•
For any requirements on product maintenance, contact Siemens Technical support
(Page 69).
•
Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge,
do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and
protect from direct sunlight, moisture and condensation.