![Siemens SIMATIC IOT2000 Series Operating Instructions Manual Download Page 16](http://html.mh-extra.com/html/siemens/simatic-iot2000-series/simatic-iot2000-series_operating-instructions-manual_374406016.webp)
5.2
Connecting the SIMATIC IOT2000 SG-Shield
Procedure
SIGNAL-
EXC-
SENSE-
EXC+
SENSE+
3
4
2
1
①
SIMATIC IOT2000 SG-Shield
②
Load cell
③
Load cell terminals
④
1. Connect the SIMATIC IOT2000 SG-Shield
①
to the four load cells
②
.
For 4-wire load cells, do not connect SENSE - and SENSE+.
The load cells are connected in parallel. There is no individual channel diagnostics.
2. Select in the software whether you have connected 4-wire or 6-wire load cells. See
section Setting the commissioning parameters (Page 19).
Connecting
5.2 Connecting the SIMATIC IOT2000 SG-Shield
SIMATIC IOT2000 SG-Shield
16
Operating Instructions, 08/2021, A5E50985404-AA
Summary of Contents for SIMATIC IOT2000 Series