Parameter
Format
Length
[bytes]
r/w
Default
Min
Max
Mod‐
bus ad‐
dress
Word swap for 32-bit values (only
for SG-Shield OEM)
0: Big endian (MSB first)
1: Little endian (LSB first)
unsigned16
2
r/w
1
0
1
4009
MODBUS RTU response delay (on‐
ly for SG-Shield OEM)
unsigned16
2
r/w
0
0
500
4010
6.5
Reading parameter values
Table 6-1
SG-Shield OEM Info
Parameter
Format
Length
[bytes]
r/w
Default
Min
Max
Modbus
address
Order number
string32
32
r
SG-Shield OEM:
7MH4647-0AA0
1
SIMAT‐
IC IOT2000 SG-
Shield:
7MH4647-0KK0
0-0AA2
-
-
6058
Serial number
string32
32
r
0
-
-
6042
FW version
string16
16
r
-
-
6138
HW version
string16
16
r
-
-
6026
HW device ID
un‐
signed16
2
r
1
0
15
6178
Device status
Bit 0: QI flag
Bit 1: Load cell input faulty
Bit 2: Checksum error
Bit 3: Checksum error (data)
Bit 4: Watchdog error
Bit 5: ADC error
Bit 6: Temperature warning
Bit 7: Firmware update error
un‐
signed16
2
r
0x FFFF
-
-
2050
Temperature
float
4
r
0.0
-50.0
+150.
0
2051
Parameter assignment
6.5 Reading parameter values
SIMATIC IOT2000 SG-Shield
Operating Instructions, 08/2021, A5E50985404-AA
21