![Siemens SIMATIC IOT2000 Series Operating Instructions Manual Download Page 18](http://html.mh-extra.com/html/siemens/simatic-iot2000-series/simatic-iot2000-series_operating-instructions-manual_374406018.webp)
5. Change the IP address.
The address must not match the address of the device.
The default IP address of the device is 192.168.200.1. Your computer must be in the same
network to communicate with the device. Your computer can have the IP address
192.168.200.2, for example.
The subnet mask is entered automatically. (255.255.255.0)
6. Click "OK".
6.2
Parameterizing SIMATIC IOT2050
Procedure
1. Download the example image (
https://support.industry.siemens.com/cs/ww/en/view/
) (operating system with pre-installed Node-Red software).
2. Write the example image to a microSD card and insert the card into the SIMATIC IOT2050.
3. Install an operating system including Node-Red software on the SIMATIC IOT2050.
Connect your PC to the SIMATIC IOT2050, Ethernet connection X1LAN P2.
4. Set up your PC.
Setting up the PC for the connection to the SIMATIC IOT2050 device (Page 17)
5. Start the Node-Red software by typing the IP address of the SIMATIC IOT2050 and the port
1880 into the Google Chrome browser. Example: http://192.168.200.1:1880
⇒ The Node-Red editor opens.
6. Install the following Node-Red libraries:
– node-red-dashboard
– node-red-contrib-modbus
– node-red-contrib-bit
– @mindconnect/node-red-contrib-mindconnect
– node-red-contrib-config
7. Download the Node-Red example program for SIMATIC IOT2000 SG-Shield (
support.industry.siemens.com/cs/ww/de/ps/17781/dl
8. Import the Node-Red example program for SIMATIC IOT2000 SG-Shield.
9. Click "Deploy".
6.3
Calibrate scale with Node-Red
Introduction
In the Node-Red example program for SIMATIC IOT2000 SG-Shield (
support.industry.siemens.com/cs/ww/de/ps/17781/dl
), the characteristic is determined with
two calibration points.
Parameter assignment
6.3 Calibrate scale with Node-Red
SIMATIC IOT2000 SG-Shield
18
Operating Instructions, 08/2021, A5E50985404-AA
Summary of Contents for SIMATIC IOT2000 Series
Page 30: ...Technical data SIMATIC IOT2000 SG Shield 30 Operating Instructions 08 2021 A5E50985404 AA ...
Page 32: ...Dimension drawings SIMATIC IOT2000 SG Shield 32 Operating Instructions 08 2021 A5E50985404 AA ...
Page 38: ...Index SIMATIC IOT2000 SG Shield 38 Operating Instructions 08 2021 A5E50985404 AA ...