7-6
CM35 Counter Module
(4) J31069-D0416-U001-A5-7618
7.2.2
Structure of the Parameter Blocks
Tables 7-5, 7-7 and 7-9 show the data structures of the three parameter blocks
and how they must be transferred to the CM35 with SFC 55 calls or I/O di-
rect accesses.
The first word of the parameter blocks contains the control word. The required
assignment is entered as an initial value in the structures.
When I/O direct accesses are parameterized (only with SIMATIC S5), the
acceptance structures must be transferred after the data structures. See tables
7-6, 7-8 and 7-10. The required assignment of the acceptance structures is
entered as an initial value.
Adhere to the information in chapter 4.2 concerning transmission of the data.
Parameter block 1
contains:
-- The time base for timers 1 to 8
-- The factor for timers 1 and 2
Table 7-5
Parameter block 1, data structure
Address
Name
Type
Initial
Value
Commentary
Para_Block_1_Data
STRUCT
+0.0
Control_word
WORD
W#16#13
Parameter block no. 1/
timer mode
+2.0
Timebase_Timer_1
BYTE
B#16#0A
Time base for timer 1
+3.0
Timebase_Timer_2
BYTE
B#16#0A
Time base for timer 2
+4.0
Timebase_Timer_3
BYTE
B#16#0A
Time base for timer 3
+5.0
Timebase_Timer_4
BYTE
B#16#0A
Time base for timer 4
+6.0
Timebase_Timer_5
BYTE
B#16#0A
Time base for timer 5
+7.0
Timebase_Timer_6
BYTE
B#16#0A
Time base for timer 6
+8.0
Timebase_Timer_7
BYTE
B#16#0A
Time base for timer 7
+9.0
Timebase_Timer_8
BYTE
B#16#0A
Time base for timer 8
+10.0
Factor_Timer_1
WORD
W#16#01
Factor for timer 1
+12.0
Factor_Timer_2
WORD
W#16#01
Factor for timer 2
=14.0
END_STRUCT
Table 7-6
Parameter block 1, acceptance structure (only for SIMATIC S5)
Address
Name
Type
Initial
Value
Commentary
Para_Block_1_Accept
STRUCT
+0.0
Control_word
WORD
W#16#53
Consistency bit = 1 /
parameter block no. 1/
timer mode
=2.0
END_STRUCT
Timer Operating Mode
Summary of Contents for SIMATIC CM35
Page 1: ...SIMATIC Counter Module CM35 Manual Release 06 2000 ...
Page 9: ...vi CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Table of Contents ...
Page 10: ...1 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Product Overview 1 ...
Page 20: ...2 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Function Description 2 ...
Page 23: ...2 4 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Function Description ...
Page 47: ...3 24 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Commissioning ...
Page 48: ...4 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Data Communication with the CM35 4 ...
Page 70: ...5 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Pulse Counter Operating Mode 5 ...
Page 98: ...7 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Timer Operating Mode 7 ...
Page 112: ...8 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Positioning Operating mode 8 ...
Page 131: ...8 20 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Positioning Operating mode ...
Page 133: ...A 2 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Literature ...
Page 134: ...B 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 EC Declaration of Conformity B ...
Page 135: ...B 2 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 EC Declaration of Conformity ...
Page 141: ...Glossary 6 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Glossary ...