8-9
CM35 Counter Module
(4) J31069-D0416-U001-A5-7618
Table 8-2
Setting an actual value
Variable:
Set_ActualValue
Para-
meter
Block
Sub-
number
Off-
set
Data
Type
Value Range
Set_ActualValue_Axis_1 1
1
6.0
DWord
-- 2,147,483,648
Set_ActualValue_Axis_2 1
2
12.0
DWord
to
+ 2,147,483,647
Set_ActualValue_Axis_3 1
3
18.0
DWord
+ 2,147,483,647
Set_ActualValue_Axis_4 1
4
24.0
DWord
When you specify the setpoint, you transfer to the module the increment
value at which the axis is to be positioned.
A hardware interrupt is generated when the axis reaches the setpoint position.
Setpoints are entered in the parameter blocks in twos complement representa-
tion as shown below.
-- 2,147,483,648
-1
0
+1
+ 2,147,483,647
8000 0000...
..FFFF FFFF..
..0..
..1..
..7FFF FFFF
Specification of the setpoint is axis--specific.
Variable:
Setpoint
Parame-
ter Block
Sub-
number
Off-
set
Data
Type
Value Range
Setpoint_Axis_1
2
1
2.0
DWord
-- 2,147,483,648
Setpoint_Axis_2
2
2
8.0
DWord
to
+ 2,147,483,647
Setpoint_Axis_3
2
3
14.0
DWord
+ 2,147,483,647
Setpoint_Axis_4
2
4
20.0
DWord
Setpoint
Positioning Operating mode
Summary of Contents for SIMATIC CM35
Page 1: ...SIMATIC Counter Module CM35 Manual Release 06 2000 ...
Page 9: ...vi CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Table of Contents ...
Page 10: ...1 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Product Overview 1 ...
Page 20: ...2 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Function Description 2 ...
Page 23: ...2 4 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Function Description ...
Page 47: ...3 24 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Commissioning ...
Page 48: ...4 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Data Communication with the CM35 4 ...
Page 70: ...5 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Pulse Counter Operating Mode 5 ...
Page 98: ...7 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Timer Operating Mode 7 ...
Page 112: ...8 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Positioning Operating mode 8 ...
Page 131: ...8 20 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Positioning Operating mode ...
Page 133: ...A 2 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Literature ...
Page 134: ...B 1 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 EC Declaration of Conformity B ...
Page 135: ...B 2 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 EC Declaration of Conformity ...
Page 141: ...Glossary 6 CM35 Counter Module 4 J31069 D0416 U001 A5 7618 Glossary ...