Optional customer keys X53/X54
The outputs X53 / X54 are intended to activate lamps in the keys.
We would recommend using 1.2 W lamps with max. 0.3 A per output.
High-side switches which switch 24 V to the lamps and limit the current during short circuits
are used as output drivers.
;
0
0
3
+LJK6LGH6ZLWFK
.7287
.7287
.7287
;
0
0
3
.7287
.7287
.7287
Figure 4-7
Schematic circuit diagram of the output circuit for X53 and X54
NOTICE
Damage to the module through induction voltages
Do not connect any relays, valves or other inductive loads.
Interface:
Optional customer keys OUT
Connector designation:
X53/X54
Connector type:
4-pin male connector
Table 4-11
Assignment of connector X53
Pin
Name
Type
Meaning
1
KT-OUT1
O
Customer key 1 lamp
2
KT-OUT2
Customer key 2 lamp
3
KT-OUT3
Customer key 3 lamp
4
M
V
Ground
Interfaces
4.3 Machine control panels
ERGOline Stage 3
Manual, 02/2015, 6FC5397-4FP40-0BA0
29