![Siemens SIMATIC Box PC Manual Download Page 24](http://html.mh-extra.com/html/siemens/simatic-box-pc/simatic-box-pc_manual_374630024.webp)
X302
The X302 interface is designed as a "high powered interface" with max. 500 mA, 5 V. The
connection between the keyboard and operator panel is established via X302.
Connector designa‐
tion:
X302; USB-B connector, 4-pin
Table 4-1
Assignment of connector X302
Pin
Signal name
Signal type
Meaning
1
P5
V
+ 5 V power supply
for external USB device
2
USB_DM0
B
Data -; channel 0
3
USB_DP0
Data +; channel 0
4
M
V
Ground
X303 A/B
These interfaces are used for the connection of simple USB extensions such as a USB mouse
or USB keyboard. They are designed as "low powered interface" with max. 100 mA, 5 V.
Connector designa‐
tion:
X303 A/B; USB connector type A, 4-pin
Table 4-2
Assignment of connector X303 A
Pin
Signal name
Signal type
Meaning
A1
1P5
V
+ 5 V power supply
for external USB device
A2
USB_DM2
B
Data -; channel 2
A3
USB_DP2
Data +; channel 2
A4
M
V
Ground
Table 4-3
Assignment of connector X303 B
Pin
Signal name
Signal type
Meaning
B1
2P5
V
+ 5 V power supply
for external USB device
B2
USB_DM3
B
Data -; channel 3
B3
USB_DP3
Data +; channel 3
B4
M
V
Ground
Interfaces
4.3 Machine control panels
ERGOline Stage 3
24
Manual, 02/2015, 6FC5397-4FP40-0BA0
Summary of Contents for SIMATIC Box PC
Page 4: ...Table of contents ERGOline Stage 3 4 Manual 02 2015 6FC5397 4FP40 0BA0 ...
Page 38: ...Interfaces 4 3 Machine control panels ERGOline Stage 3 38 Manual 02 2015 6FC5397 4FP40 0BA0 ...
Page 42: ...Operating ERGOline Stage 3 42 Manual 02 2015 6FC5397 4FP40 0BA0 ...
Page 54: ...Spare parts 8 2 Replacement ERGOline Stage 3 54 Manual 02 2015 6FC5397 4FP40 0BA0 ...
Page 56: ...Accessories ERGOline Stage 3 56 Manual 02 2015 6FC5397 4FP40 0BA0 ...
Page 58: ...Index ERGOline Stage 3 58 Manual 02 2015 6FC5397 4FP40 0BA0 ...