Messages
12-102
©
Siemens AG 2007 All Rights Reserved
SICLOCK
®
TC 400
Default processor loaded
Warning
The default processor has been loaded when starting
Input 1, 2: DCF77 OK
Information
Correct DCF reception has been detected again after a fault.
Input 1, 2: DCF77 signal faulty
Information
A fault has been detected in the DCF77 signal during stable reception.
Input 1, 2: GPS OK
Information
Correct GPS reception has been detected again after a fault.
Input 1, 2: GPS signal faulty
Information
A fault has been detected in the GPS signal during stable reception.
Input 1, 2: signal timeout
Application
(alarm)
A signal has not been received within the parameterized timeout during activated mon-
itoring.
Check the status display, see
Radio clocks via terminals
(Section 9.1.1). If "no sig-
nal" is displayed in the status, check the wiring.
Input 1, 2: telegram OK
Information
A serial format has been detected (for the first time after a failure).
Input 1, 2: telegram cannot be decoded
Information
The serial format cannot be decoded.
Firmware has been updated
System and
information
A firmware update has been performed and the firmware has been updated.
Firmware has NOT been updated
System and
information
A firmware update has been performed, but the firmware could not be updated.
Flash file system has been formatted
System
The file system has been formatted.
Protected Synchronization
Application
(alarm)
The protected synchronization has been activated as a discontinuity has been detected
in the external synchronization.
The message indicates an error of the external synchronization. See also
Synchroni-
zation
(Section 9.3.2).
Internal error, please contact the support
System
The exact specification of the error is contained in the message text and may be of
importance for the support (hotline).
Processor has been updated
System and
information
A processor update has been performed and the processor has been updated.
Table 12-1
Message overview with event type and brief description
Summary of Contents for SICLOCK TC 400
Page 1: ...SICLOCK s SICLOCK TC 400 Plant Central Clock Operating Instructions 09 2007 ...
Page 2: ......
Page 6: ...Preface Preface 4 Siemens AG 2007 All Rights Reserved SICLOCK TC 400 Operating Instructions ...
Page 10: ...Table of contents Contents 8 Siemens AG 2007 All Rights Reserved SICLOCK TC400 ...
Page 20: ...Description 2 18 Siemens AG 2007 All Rights Reserved SICLOCK TC 400 ...
Page 26: ...Hardware Description 3 24 Siemens AG 2007 All Rights Reserved SICLOCK TC 400 ...
Page 34: ...Installation 5 32 Siemens AG 2007 All Rights Reserved SICLOCK TC 400 ...
Page 68: ...Configuration Tool 7 66 Siemens AG 2007 All Rights Reserved SICLOCK TC 400 ...
Page 100: ...Parameter Table 10 98 Siemens AG 2007 All Rights Reserved SICLOCK TC 400 ...
Page 110: ...Technical Data 13 108 Siemens AG 2007 All Rights Reserved SICLOCK TC 400 ...
Page 112: ...Dimension Drawing 14 110 Siemens AG 2007 All Rights Reserved SICLOCK TC 400 ...
Page 114: ...Circuit Diagrams 15 112 Siemens AG 2007 All Rights Reserved SICLOCK TC 400 ...
Page 116: ...Spare Parts Accessories 16 114 Siemens AG 2007 All Rights Reserved SICLOCK TC 400 ...
Page 122: ...ESD Guidelines B 120 Siemens AG 2007 All Rights Reserved SICLOCK TC 400 ...
Page 130: ...Glossary D 128 Siemens AG 2007 All Rights Reserved SICLOCK TC 400 ...
Page 133: ......