background image

SICAM SGU Devices

 

s

 

 

7XV5676 

 

 

Product Information 

 

E50417-B1050-C554-A4, Edition  03.2015 

 
 
 
 
 
 

 

 

Disclaimer of Liability 

Although we have carefully checked the contents of this publication for conformity with 
the hardware and software described, we cannot guarantee complete conformity since 
errors cannot be excluded. 

The information provided in this document is checked at regular intervals and any correc-
tions that might become necessary are included in the next releases. Any suggestions for 
improvement are welcome. 

Subject to change without prior notice.

 

Copyright 

Copyright © Siemens AG 2014 – All Rights Reserved 

The reproduction, transmission or use of this document or its contents is not permitted 
without express written authority. Offenders will be liable for damages. All rights, including 
rights created by patent grant or registration of a utility model or design, are reserved.

 

Registered Trademarks 

SICAM® is a registered trademark of SIEMENS AG. All other product and brand names 
in this manual might be trademarks, the use of which by third persons for their purposes 
might infringe the rights of their respective owners. 

Open Source Software 

The product contains, among other things, Open Source Software developed by third 
parties. The Open Source Software used in the product and the license agreements 
concerning this software can be found in the Readme_OSS. 

These Open Source Software files are protected by copyright. Your compliance with 
those license conditions will entitle you to use the Open Source Software as foreseen in 
the relevant license. In the event of conflicts between Siemens license conditions and the 
Open Source Software license conditions, the Open Source Software conditions shall 
prevail with respect to the Open Source Software portions of the software. 

The Open Source Software is licensed royalty-free. Insofar as the applicable Open 
Source Software License Conditions provide for it you can order the source code of the 
Open Source Software from your Siemens sales contact - against payment of the ship-
ping and handling charges - for a period of at least 3 years since purchase of the Product. 
We are liable for the Product including the Open Source Software contained in it pursuant 
to the license conditions applicable to the Product. Any liability for the Open Source 
Software beyond the program flow intended for the Product is explicitly excluded. Fur-
thermore any liability for defects resulting from modifications to the Open Source Soft-
ware by you or third parties is excluded. We do not provide any technical support for the 
Product if it has been modified. 

Notes on Safety 

This document contains notes that must be adhered to for your own personal safety and 
to avoid damage to property. However, it does not constitute a complete description of all 
safety measures required for installation, service, and maintenance of the equipment 
(module, device) in question. Details are to be taken from the device manual and those 
are mandatory. 

 

 

WARNING 

Danger of severe personal injury or substantial damage to property 

Hazardous voltages may occur in devices and modules during operation 
depending on the design and application. 

 

Always observe the instructions given in “Qualified Electrical Engi-
neering Personnel” below. 

Qualified Electrical Engineering Personnel 

Only qualified electrical engineering personnel may commission and operate the equip-
ment (module, device) described in this document. 

Qualified electrical engineering personnel in the sense of this document are people who 
can demonstrate technical qualifications as electrical technicians. These persons may 
commission, isolate, ground and label devices, systems and circuits according to the 
standards of safety engineering. 

 

 

 

Use as Prescribed 

The equipment (device, module) may only be used for such applications as set out in the 
catalogs and the technical description, and only in combination with third-party equipment 
recommended and approved by Siemens. 

If the device is not used in accordance with this product information, the scheduled 
protection is impaired. 

Correct and safe operation of the product requires adequate transportation, storage, 
installation, and assembly, appropriate use, and maintenance as well as the attention of 
the WARNINGs. 

During the operation of electric equipment, it is unavoidable that certain parts of this 
equipment will carry hazardous voltages. Severe injury or material damage can occur if 
the appropriate 

measures

 are not taken. 

The limiting values indicated in the product information and the manuals must not be 
exceeded; this also refers to testing and commissioning. 

Further Support 

For any questions concerning your system, please contact your Siemens representative. 
The Siemens Customer Support Center provides around-the-clock support. 

 

Phone: +49 (1805) 24-7000 

 

Fax: +49 (1805) 24-2471 

 

Internet: http://www.siemens.com/sicam 

 

e-mail: [email protected] 

Statement of Conformity 

 

 

Low-voltage Directive 2006/95/EC 

EMC Council Directive 2004/108/EC 

EMC test acc. to 301489-1-7 

ETSI standard EN 301 511 

This conformity has been established by means of tests conducted by 
Siemens AG according to the Council Directive in agreement with the 
generic standards EN 61000-6-2 and EN 61000-6-4 for the EMC 
directives, and with the standard EN 61326-1 for the low-voltage 
directive. 

Further Standards 

This product is UL-certified, based on the technical data: 

- acc. to Standard UL 61010-1, third edition; UL File No.: E228586 

 

Open-type Measuring Equipment 

2UD1 

For further information see UL database on the internet

http://ul.com

Chose 

Online 

Certifications Directory

 and insert E228586 under 

UL File Number

Used Symbols 

No. 

Symbol 

Description 

 

Direct current: IEC 60417-5031 

 

Alternating current: IEC 60417-5032 

 

Direct and alternating current: IEC 60417-5033 

 

Three-phase alternating current 

 

Earth (ground) terminal: IEC 60417-5017 

 

Protective conductor terminal: IEC 60417-5019 

 

Caution, risk of electric shock 

 

Caution, risk of danger: ISO 7000-0434 

Read and understand these instructions and the relevant manual before installing, 
operating, or maintaining the device. 

Check on our homepage whether a new firmware version is available and update 
your firmware if necessary. 

You can find the manual and the firmware via the download area in the Internet 
under: 

http://www.siemens.com/sicam

 

 

Summary of Contents for SICAM SGU 7XV5676

Page 1: ...rische Spannungen auftreten Beachten Sie immer die nachfolgenden Hinweise unter Elektro technisch qualifiziertes Personal und die Sicherheitshinweise Elektrotechnisch qualifiziertes Personal Nur elektrotechnisch qualifiziertes Personal darf ein in diesem Dokument beschriebenes Betriebsmittel Baugruppe Gerät in Betrieb setzen und betreiben Elektrotechnisch qualifiziertes Personal im Sinne der siche...

Page 2: ...ie Vollständigkeit des beigelegten Zubehörs Bewahren Sie die Verpackung für eine mögliche Einlagerung oder den Weitertrans port auf Senden Sie das beschädigte Gerät unter Angabe des Mangels an den Hersteller zurück HINWEIS Siemens empfiehlt das Gerät mindestens 2 Stunden im Betriebsraum liegen zu lassen bevor Sie es in Betrieb nehmen um einen Tempera turausgleich zu schaffen und um Feuchtigkeit so...

Page 3: ...ng Bedienvoraussetzungen Für die meisten Bedienfunktionen ist die Eingabe von Passwörtern erforderlich Dies gilt für alle Eingaben die die Funktionen des Gerätes betreffen Für das Auslesen von Daten Meldungen und Diagnosewerten ist kein Passwort erforder lich HINWEIS Bei Auslieferung sind folgende Passwörter voreingestellt Aktivierungspasswort 000000 Wartungspasswort 311299 Nach abgeschlossener In...

Page 4: ...enen Verkehrsträger Sonderbestimmung 188 aus den UN Empfehlungen für den Transport gefährlicher Güter Sonderbe stimmung A45 der IATA Gefahrgutvorschrift und den technischen Anleitungen der ICAO Dies gilt nur für die Originalbatterie oder Original Ersatzbatterien Technische Daten SICAM SGU 7XV5676 0JJ00 7AA1 Klemmenblock H Versorgungsspannung Gleichspannung Nenneingangsspannung DC 24 V bis 250 V Zu...

Page 5: ...s SICAM SGU Geräte 7XV5676 Produktinformation E50417 B1050 C554 A4 Ausgabe 03 2015 5 ...

Page 6: ...rty Hazardous voltages may occur in devices and modules during operation depending on the design and application Always observe the instructions given in Qualified Electrical Engi neering Personnel below Qualified Electrical Engineering Personnel Only qualified electrical engineering personnel may commission and operate the equip ment module device described in this document Qualified electrical e...

Page 7: ...al condition Check the enclosed accessories against the delivery note to make sure that every thing is complete Keep the packing in case the devices must be stored or transported elsewhere Return damaged devices to the manufacturer stating the defect NOTE Before commissioning the device leave it in the final operating room for at least 2 hours This allows it to reach room temperature and to preven...

Page 8: ...ll be separated from other circuits with respect to the end use requirements Operation Prerequisites Most control functions require the input of passwords This applies to all entries affecting the device functions No password is required to read out data indications and diagnostic data NOTE The device comes delivered with the following default passwords Activation password 000000 Maintenance passw...

Page 9: ...us Goods Model Regulations and Special Provision A45 of the IATA Dangerous Goods Regulation and the ICAO Technical Instructions This is only valid for the original battery or original spare bat teries Technical Data SICAM SGU 7XV5676 0JJ00 7AA1 Terminal Block H Supply Voltage Direct Voltage Rated input voltages DC 24 V to 250 V Admissible input voltage tolerance 20 Permitted ripple of the input vo...

Page 10: ...SICAM SGU Devices s 7XV5676 Product Information 10 E50417 B1050 C554 A4 Edition 03 2015 ...

Page 11: ...0 7AA1 Klemmenseite Terminal Side 2 SICAM SGU 7XV5676 xJJ70 8AA2 Klemmenseite Terminal Side 3 SICAM SGU 7XV5676 xJL70 8AA2 Klemmenseite Terminal Side 4 SICAM SGU 7XV5676 Hutschienenseite DIN Rail Side 5 SICAM SGU 7XV5676 Geräteoberseite Batteriefachdeckel Device Top Side Cover of Battery Compartment 6 SICAM SGU 7XV5676 Hutschienenmontage DIN rail Assembly ...

Page 12: ... SGU Devices s 7XV5676 Produktinformation Product Information 12 E50417 B1050 C554 A4 Ausgabe Edition 03 2015 7 SICAM SGU 7XV5676 0JJ00 7AA1 Maßbild Dimension Drawing 8 SICAM SGU 7XV5676 xJx70 8AA2 Maßbild Dimension Drawing ...

Reviews: