Approvals and markings
SCALANCE X-200
274
Operating Instructions, 12/2011, A5E00349864-19
Device type
SCALANCE
IEC 60068-2-6 vibration
IEC 60068-2-27 shock
X204 IRT PRO 5 – 9 Hz: 3.5 mm
9 – 150 Hz: 1 g
10 cycles per axis
15 g, 11 ms duration
6 shocks per axis
X202-2P IRT
PRO
5 – 9 Hz: 3.5 mm
9 – 150 Hz: 1 g
10 cycles per axis
15 g, 11 ms duration
6 shocks per axis
X201-3P IRT
PRO
5 – 9 Hz: 3.5 mm
9 – 150 Hz: 1 g
10 cycles per axis
15 g, 11 ms duration
6 shocks per axis
X202-2P IRT
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 11 ms duration
6 shocks per axis
X201-3P IRT
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 11 ms duration
6 shocks per axis
X200-4P IRT
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 11 ms duration
6 shocks per axis
Note
The interfaces of the X-200 IE switches can be divided into groups each with 4 ports:
P1 to P4
P5 to P8
P9 to P12
etc.
If only ports of different port groups are used, the device meets the requirements for
Environment B in compliance with IEEE 802.3, Section 33.4.1.1. If ports of the same port
group are used, the requirements for Environment A are met.
Summary of Contents for SCALANCE X-200
Page 12: ...Table of contents SCALANCE X 200 12 Operating Instructions 12 2011 A5E00349864 19 ...
Page 284: ...Technical specifications SCALANCE X 200 284 Operating Instructions 12 2011 A5E00349864 19 ...
Page 288: ...References SCALANCE X 200 288 Operating Instructions 12 2011 A5E00349864 19 ...
Page 294: ...Dimension drawings SCALANCE X 200 294 Operating Instructions 12 2011 A5E00349864 19 ...