Connecting up
6.5 Connecting a power supply adapter
SCALANCE W786 outdoor access point
50
Operating Instructions, 06/2013, A5E02280428-08
The following applies to the PS791-2AC (AC 100 – 240 V) only:
WARNING
Danger from line voltage
The strain relief clamp may damage the insulation under unfavorable circumstances. You
run the risk of encountering danger from line voltage through the strain relief clamp.
For a line with 100 to 240 VAC use an insulated strain relief clamp only; it is included in the
scope of delivery for the power sup
ply adapter!
How to remove the power supply adapter
Follow the steps below to remove a power supply adapter from a SCALANCE W786:
WARNING
Danger from line voltage
Only electrical specialists may open the device and remove the power supply adapter!
Connect or disconnect power supply cables only when the power
is turned off!
1.
Disconnect the power supply cable from the power supply adapter.
2.
Loosen the securing screw of the power supply adapter (position A in the figure above).
3.
Pull the loop (position B in the figure above) to remove the connector on the rear of the
power supply adapter from the socket in the housing and remove the power supply
adapter.