Connecting up
6.2 Suitable cables for the SCALANCE W786
SCALANCE W786 outdoor access point
40
Operating Instructions, 06/2013, A5E02280428-08
6.2
Suitable cables for the SCALANCE W786
Cable specification
The following table lists the requirements for a cable depending on the use case.
Application
Specification
Direct 48 V DC supply
•
Round cable cross-section with
6 to 8 mm diameter.
•
Permitted tensile load at least
100 N.
•
UL listing: Type PLTC or ITC
Power supply adapter 12 - 24 V DC
•
Round cable cross-section with
6 to 8 mm diameter.
•
Permitted tensile load at least
100 N.
•
UL listing: Type PLTC or ITC
Power supply adapter 100 - 240 V AC
•
Round cable cross-section with
6 to 8 mm diameter.
•
Three-core cable with 0.5 - 1.5 mm
2
cross
section of the individual cores.
•
Permitted tensile load at least
100 N.
Ethernet
IE FC TP Standard Cable GP 2 x 2 (type A)
Order no. 6XV1 840-2AH10
IE TP Torsion Cable 2 x 2 (type C)
Order no. 6XV1 870-2F
IE FC TP Trailing Cable 2 x 2 (type C)
Order no. 6XV1 840 3AH10
UL listing: Type PLTC or ITC (the three named types
have this approval)
Multimode FO cable
FO Standard Cable GP
Order no. 6XV1 873-2A
Minimum bending radius 65 mm.
You will find detailed information on preassembled
cable lengths and connectors in the catalog "IK PI".
Multimode FO cable
FO Robust Cable GP 2G50/125/900
Order no. 6XV1873-2R
(expected to be available as of 03/2010)
Halogen-free, UV-resistant cable for indoor and
outdoor use for ambient temperatures -40 °C ... +70
°C.