Connecting up
6.3 Connecting the cables
SCALANCE W786 outdoor access point
44
Operating Instructions, 06/2013, A5E02280428-08
4.
Seal all openings not required for cables with sealing plugs (position D in the figure
above).
5.
Fit these sealing plugs in a strain relief clamp. The lower surrounding notch must be
enclosed by the toothing of the strain relief clamp (as shown in the figure below). Press
the strain relief clamp into the housing until the sealing plug is located completely in the
opening of the housing seal.
Figure 6-2
Securing a sealing plug with a strain relief clamp
Note
Keep unused sealing plugs and strain relief clamps for later use.
Points to note when connecting an oval FO cable
Note
The following information does not apply to the FO Robust Cable GP 2G50/125/900 (order
no. 6XV1873-2R). This cable type has a round cross-section and does not need additional
adhesive sealing foil.
The oval FO cable specified for use with the SCALANCE W786 FO Standard Cable GP
(order no. 6XV1 873-2A) does not have a circular cross section. As a result, remember the
following points when connecting up such cables:
Seal
Fit the supplied adhesive sealing foil at the point where the cable goes through the housing
seal. Only then will you achieve perfect sealing of the housing. Follow the steps outlined
below:
1.
Remove the protective foil and wind the adhesive sealing foil completely around the oval
FO cable at the appropriate position transverse to the cable.
Strain relief clamp
When you fit the strain relief clamp, make sure that the FO cable is in the correct position.
The shorter sides of the cable must make contact with the toothing of the strain relief clamp.