Connecting up
6.5 Connecting a power supply adapter
SCALANCE W786 outdoor access point
Operating Instructions, 06/2013, A5E02280428-08
49
Figure 6-6
Using a power supply adapter in a SCALANCE W786
Follow the steps below to fit and connect a power supply adapter:
1.
Fit the power supply adapter in the SCALANCE W786 as shown in the figure above. The
connector on the rear of the power supply adapter must engage fully in the socket of the
housing. The entire rear surface of the power supply adapter must make contact with the
inner surface of the SCALANCE W786.
NOTICE
Only use the loop (position B in the figure above) to remove the power supply adapter
from the SCALANCE W786! This prevents the connector skewing on the back of the
power supply adapter and breaking off.
2.
Connect the power supply adapter and the SCALANCE W786 with the screw supplied
with the power supply adapter (position A in the figure above).
3.
Connect the cable for the power supply. The assignment of the contacts is illustrated in
the figure above.
4.
Secure the power supply cable with a strain relief clamp. For more detailed information on
this topic, refer to the section "Connecting the cables".