Service
Protocol/
Port number
Default port status
Configurable
Authenti‐
cation
Encryp‐
tion
2)
Local access
External ac‐
cess
1)
Port
Serv‐
ice
SINEMA RC
HTTPS/443
and TCP/UDP
depending on
the server
configuration
Outgoing only Outgoing on‐
ly
✓
✓
✓
✓
SMTP Client
TCP/25
Outgoing only Outgoing on‐
ly
✓
✓
--
--
SMTP (se‐
cure)
TCP/465
TCP/587
Outgoing only Outgoing on‐
ly
✓
✓
Optional
✓
SNMPv1/v2c UDP/161
Open
Closed
✓
✓
--
--
SNMPv3
Server
UDP/161
Open
Closed
✓
✓
Optional
Optional
SNMP Trap
UDP/161
Open
Closed
✓
✓
Optional
Optional
SNTP Client
UDP/123
Closed
Closed
✓
✓
--
--
SSH CLI
TCP/22
Open
Closed
✓
✓
✓
✓
Syslog Client UDP/514
Outgoing only Outgoing on‐
ly
✓
✓
--
--
Syslog Client
TLS
TCP/6514
Outgoing only Outgoing on‐
ly
✓
✓
--
✓
Telnet
TCP/23
Closed
Closed
✓
✓
✓
--
TFTP
UDP/69
Outgoing only Outgoing on‐
ly
✓
✓
--
--
TIA Portal
Cloud Con‐
nector
6)
TCP/9023
Closed
Closed
✓
✓
--
--
TCP Event
TCP/26864
Closed
Closed
✓
✓
--
--
SMS Relay
7)
TCP/26864
Closed
Closed
✓
✓
--
--
VXLAN
8)
UDP/4789
Closed
Closed
✓
✓
--
--
1)
With SCALANCE M826 and M804PB, only access via vlan1 is possible in the delivery state
(factory setting).
2)
You can find additional information on the encryption methods used in the WBM appendix
"Ciphers used".
3)
Only open with SCALANCE M826
4)
Only open with SCALANCE S615
5)
Only closed with SCALANCE S615
6)
Not available with SCALANCE MUM85x
7)
Only available with the SCALANCE M87x and MUM85x
8)
Only available with SCALANCE MUM85x
The following is a list of all available Layer 2 services through which the device can be
accessed.
Security recommendations
SCALANCE M826
Operating Instructions, 10/2022, C79000-G8976-C362-07
17
Summary of Contents for SCALANCE M812
Page 10: ...Safety notices SCALANCE M826 10 Operating Instructions 10 2022 C79000 G8976 C362 07 ...
Page 58: ...Maintenance and cleaning SCALANCE M826 58 Operating Instructions 10 2022 C79000 G8976 C362 07 ...
Page 62: ...Technical specifications SCALANCE M826 62 Operating Instructions 10 2022 C79000 G8976 C362 07 ...