background image

Installing the Device

2.5.1 Connecting High AC/DC Power

1. Connect the power supply terminal block to the device.

4

1

3

2

     1    

European-style (Euroblock) Terminal Block

     2    

Positive/Live (+/L) Terminal

     3    

Ground Terminal

     4    

Negative/Neutral (-/N) Terminal

Figure 2.5

AC Terminal Block Wiring – European-style (Euroblock) Terminal Block for HIP

Power Supplies

4

5

6

4

1

5

1

6

2

3

     1    

Not Connected

     2    

Removable Screw Terminal Block

     3    

Non-removable Screw Terminal Block

     4    

Positive/Live (+/L) Terminal

     5    

Ground Terminal

RUGGEDCOM RX1501

Installation Manual, 05/2020, C79000-G8976-1054-17

13

All manuals and user guides at all-guides.com

Summary of Contents for RUGGEDCOM RX1501

Page 1: ...Edition 05 2020 Installation Manual SIMATIC NET Rugged Multi Service Platforms RUGGEDCOM RX1501 https www siemens com All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...tforms RUGGEDCOM RX1501 Installation Manual Preface Introduction 1 Installing the Device 2 Device Management 3 Modules 4 Technical Specifications 5 Certification 6 05 2020 C79000 G8976 1054 17 All manuals and user guides at all guides com ...

Page 3: ...o based on their training and experience are capable of identify ing risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufacturers are used these must...

Page 4: ...ocedure 6 2 2 Unpacking the Device 6 2 3 Mounting the Device 7 2 3 1 Mounting the Device to a Rack 7 2 3 2 Mounting the Device on a DIN Rail 8 2 3 3 Mounting the Device to a Panel 9 2 4 Connecting the Failsafe Alarm Relay 10 2 5 Connecting Power 11 2 5 1 Connecting High AC DC Power 12 2 5 2 Connecting Low DC Power 15 3 Device Management 21 3 1 Connecting to the Device 21 3 2 Configuring the Device...

Page 5: ...chanical Specifications 46 5 5 Dimension Drawings 46 6 Certification 51 6 1 Approvals 51 6 1 1 UL 51 6 1 2 TÜV SÜD 51 6 1 3 European Union EU 52 6 1 4 FCC 53 6 1 5 FDA CDRH 53 6 1 6 ISED 53 6 1 7 ACMA 54 6 1 8 RoHS 54 6 1 9 Other Approvals 54 6 2 EMC and Environmental Type Tests 55 iv RUGGEDCOM RX1501 Installation Manual 05 2020 C79000 G8976 1054 17 All manuals and user guides at all guides com ...

Page 6: ... support industry siemens com cs ww en view 109747072 RUGGEDCOM SFP Transceivers Catalog https support industry siemens com cs ww en view 109482309 Accessing Documentation The latest user documentation for RUGGEDCOM RX1501 is available online at https support industry siemens com To request or inquire about a user document contact Siemens Customer Support Registered Trademarks RUGGEDCOM and ROS ar...

Page 7: ...esentative Training Siemens offers a wide range of educational services ranging from in house training of standard courses on networking Ethernet switches and routers to on site cus tomized courses tailored to the customer s needs experience and application Siemens Educational Services team thrives on providing our customers with the es sential practical skills to make sure users have the right kn...

Page 8: ...als Submit SRs or check on the status of an existing SR Contact a local Siemens representative from Sales Technical Support Training etc Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 264 0006 Tel 1 905 856 5288 Fax 1 905 85...

Page 9: ...Preface Contacting Siemens viii RUGGEDCOM RX1501 Installation Manual 05 2020 C79000 G8976 1054 17 All manuals and user guides at all guides com ...

Page 10: ...C 40 to 185 F operat ing temperature no fans Failsafe output relay for critical fail ure or error alarming Universal Power Supply Options Single removable power supply module Fully integrated power supply no external adapter Input voltage ranges 13 36 VDC and 37 72 VDC or 85 264 VAC and 88 300 VDC for worldwide operabili ty CSA UL 60950 1 safety approved to 85 C 185 F Physical Ports Field replacea...

Page 11: ...on refer to the RUGGEDCOM ROX Configuration Manual for the RUGGEDCOM RX1501 Lamp Test Alarm Cut Off LT ACO Button This button performs two functions Press and hold this button to test all indicator LEDs Press and release this button to acknowledge an active alarm Power Status LEDs Indicates the status of the power modules I The power module is receiving power O The power module is supplying power ...

Page 12: ...ety Earth 1 4 Decommissioning and Disposal Proper decommissioning and disposal of this device is important to prevent malicious users from obtaining proprietary information and to protect the environment Decommissioning This device may include sensitive proprietary data Before taking the device out of service either permanently or for maintenance by a third party make sure it has been fully decomm...

Page 13: ...Industry Association TIA TIA EIA 568 A wiring standard that characterizes minimum cabling performance specifications required for proper Gigabit Ethernet operation For reliable error free data communication new and pre existing communication paths should be verified for TIA EIA 568 A compliance The following table summarizes the relevant cabling standards Cabling Category 1000Base TX Compliant Req...

Page 14: ...dio frequency base sta tions as defined in FCC OET Bulletin 65 http transition fcc gov Bureaus Engi neering_Technology Documents bulletins oet65 oet65 pdf The emitted radiation should be as little as possible To achieve minimum RF exposure install the device when it is configured not to transmit and set it to operational mode remotely rather than having a technician enable transmission on site For...

Page 15: ... on the device 1 Review the relevant certification information for any regulatory requirements For more information refer to Approvals Page 51 2 Review the RUGGEDCOM RX1500 Series Modules Catalog for special installation or regulatory requirements related to the modules installed in the device In the case of cellular modem line modules this includes antenna installation and reg ulatory requirement...

Page 16: ...added stability NOTICE Vibration hazard risk of damage to the device Always use four rack mount adapters two at the front of the device and two at the rear when installing the device in high vibration or seismically active locations NOTICE Electrical mechanical hazard risk of damage to the device Before installing the device in a rack make sure of the following When installing the device in a clos...

Page 17: ...adapters to be installed up to 25 mm 1 in from the face of the device 3 3 1 2 1 Rear 2 Front 3 Rack Mount Adapter Figure 2 1 Rack Mount Adapters 2 If required install adapters on the opposite side of the device to protect from vi brations 3 Insert the device into the rack 4 Secure the adapters to the rack using the supplied hardware 2 3 2 Mounting the Device on a DIN Rail For DIN rail installation...

Page 18: ...ting 2 Install one of the supplied screws on either side of the device to secure the adapters to the DIN rails 2 3 3 Mounting the Device to a Panel For panel installations the RUGGEDCOM RX1501 can be equipped with panel DIN rail adapters pre installed on each side of the chassis The adapters allow the device to be attached to a panel using screws RUGGEDCOM RX1501 Installation Manual 05 2020 C79000...

Page 19: ...ns The NO Normally Open contact is closed when the unit is powered and there are no ac tive alarms If the device is not powered or if an active alarm is configured the relay opens the NO contact and closes the NC Normally Closed contact Note Control of the failsafe relay output is configurable through RUGGEDCOM RX1501 One common application for this relay is to signal an alarm if a power failure o...

Page 20: ... serious personal injury or death Make sure all power sources are off before servicing the power module terminals IMPORTANT Use minimum 16 gage copper wiring when connecting terminal blocks The maximum wire length between the terminal block and power source must not exceed 6 m 20 ft for 24 V power supplies or 18 m 60 ft for 48 V power supplies For 125 230 VAC rated equipment an appropriately rated...

Page 21: ...and or damage to the device Make sure the supplied cover is always installed over high voltage screw terminal blocks NOTICE Electrical hazard risk of damage to equipment Do not connect AC power cables to a 12 24 or 48 VDC power supply terminal block Damage to the power supply may occur 12 RUGGEDCOM RX1501 Installation Manual 05 2020 C79000 G8976 1054 17 All manuals and user guides at all guides co...

Page 22: ...rminal 4 Negative Neutral N Terminal Figure 2 5 AC Terminal Block Wiring European style Euroblock Terminal Block for HIP Power Supplies 4 5 6 4 1 5 1 6 2 3 1 Not Connected 2 Removable Screw Terminal Block 3 Non removable Screw Terminal Block 4 Positive Live L Terminal 5 Ground Terminal RUGGEDCOM RX1501 Installation Manual 05 2020 C79000 G8976 1054 17 13 All manuals and user guides at all guides co...

Page 23: ... from the power source to the positive live L termi nal on the terminal block 3 Connect the negative wire from the power source to the neutral negative N terminal on the terminal block 4 For screw terminal blocks install the safety cover 4 3 2 1 1 Screw 2 Safety Cover 3 Screw Terminal Block 4 RUGGEDCOM RX1501 Device Figure 2 7 Assembling the Safety Cover 5 Using a braided wire or other appropriate...

Page 24: ...d Connection 7 Install the safety cover over the terminal block 2 5 2 Connecting Low DC Power To connect a low DC power supply to the device do the following NOTICE Electrical hazard risk of damage to equipment Do not connect AC power cables to a 12 24 or 48 VDC power supply terminal block Damage to the power supply may occur Note The RUGGEDCOM RX1501 works with both positive VDC power supplies an...

Page 25: ...inal 4 Ground Terminal Figure 2 9 DC Terminal Block Wiring European style Euroblock Terminal Block for 12P 24P and 48P Power Supplies 4 5 6 5 1 6 1 4 2 3 1 Not Connected 2 Removable Screw Terminal Block 3 Non removable Screw Terminal Block 4 Positive Terminal 5 Negative Terminal 16 RUGGEDCOM RX1501 Installation Manual 05 2020 C79000 G8976 1054 17 All manuals and user guides at all guides com ...

Page 26: ...Positive Terminal 4 Negative Terminal 5 Ground Terminal Figure 2 11 DC Terminal Block Wiring European style Euroblock Terminal Block for 12P 24P and 48P Power Supplies 3 4 5 6 2 5 1 4 1 6 1 Not Connected 2 Removable Screw Terminal Block 3 Non removable Screw Terminal Block 4 Positive Terminal RUGGEDCOM RX1501 Installation Manual 05 2020 C79000 G8976 1054 17 17 All manuals and user guides at all gu...

Page 27: ...e no bare metal is exposed beyond the safety cover 2 Connect the positive wire from the power source to the positive terminal on the terminal block 3 Connect the negative wire from the power source to the negative terminal on the terminal block 4 For screw terminal blocks install the safety cover 4 3 2 1 1 Screw 2 Safety Cover 3 Screw Terminal Block 4 RUGGEDCOM RX1501 Device Figure 2 13 Assembling...

Page 28: ...he lug is tight ened to 1 1 N m 9 5 lbf in 3 2 1 4 1 10 Ring Lug 2 10 32 Screw 3 Connection from External Power Source 4 Ground Connection Figure 2 14 Ground Connection 6 Install the safety cover over the terminal block This is mandatory for 48 VDC and 48 VDC power supplies RUGGEDCOM RX1501 Installation Manual 05 2020 C79000 G8976 1054 17 19 All manuals and user guides at all guides com ...

Page 29: ...Installing the Device 2 5 2 Connecting Low DC Power 20 RUGGEDCOM RX1501 Installation Manual 05 2020 C79000 G8976 1054 17 All manuals and user guides at all guides com ...

Page 30: ...only as temporary connections during initial configuration or troubleshooting The serial console port implements RS232 DCE Data Communication Equipment on a DB9 connector The following is the pin out for the port 1 5 9 6 Figure 3 1 Serial DB9 Console Port Pin Name Description 1 DCD Data Carrier Detect 2 RX Receive Data 3 TX Transmit Data 4 DTR Data Terminal Ready 5 GND Signal Ground 6 DSR Data Set...

Page 31: ... support Ultra Physical Contact UPC cable connectors 3 2 Configuring the Device Once the device is installed and connected to the network it must be configured All configuration management is done via the RUGGEDCOM RX1501 interface For more information about configuring the device refer to the RUGGEDCOM ROX Configura tion Manual associated with the installed software release 3 3 Accessing the Comp...

Page 32: ...h this device Removing the CF card in any scenario other than those described in this section Inserting the CF card To insert the CF card into the device do the following IMPORTANT The device should only be powered on when the CF card is present 1 Make sure the device is powered down 2 Remove the CF card access panel 3 Insert the CF card into the slot until it is fully seated 2 1 1 CompactFlash Ca...

Page 33: ... 2 Remove the CF card access panel 3 2 1 1 Ejector Button 2 CompactFlash Card 3 Access Panel Figure 3 4 Removing the CF Card 3 Press the ejector button to the left of the CF card and then pull the card out 4 Secure the CF card access panel to the chassis 24 RUGGEDCOM RX1501 Installation Manual 05 2020 C79000 G8976 1054 17 All manuals and user guides at all guides com ...

Page 34: ...are to determine which ports are equipped on the device For more information refer to the RUGGEDCOM ROX Configuration Manual for the device 4 1 Requirements and Restrictions Before installing modules in the device consider the following restrictions and re quirements Module Support Slots 1 and 2 are reserved for 2 port copper and fiber Ethernet modules only Only one T1 E1 WAN module and up to two ...

Page 35: ... Port Copper M12 RJ45 4 W 4 Port Copper M12 RJ45 5 W 6 Port Copper M12 RJ45 5 W WAN T1 E1 3 W Serial S01 3 W Example A device with the following modules installed would exceed the power budget for line modules 41 5 W Module Quantity Consumption RUGGEDCOM APE1808 2 24 W 2 Port Fiber Optic FG50 SFPs 2 14 W 6 Port Copper M12 RJ45 1 5 W Total Consumption 43 W 4 2 Available Modules The following is a l...

Page 36: ... 6GK6015 0AL18 0AA0 Standard 6GK6015 0AL18 0AA1 Conformal Coated RUGGEDCOM RX1500PN PS 24 Specifications Input Range 13 to 36 VDC Terminal Type Non re movable Screw Article Numbers 6GK6015 0AL11 0AA0 Standard 6GK6015 0AL11 0AA1 Conformal Coated RUGGEDCOM RX1500PN PS 24 shipped from 2019 on Specifications Input Range 13 to 36 VDC Terminal Type Remov able Screw Article Numbers 6GK6015 0AL11 0AA0 Sta...

Page 37: ...style Euroblock Article Numbers 6GK6015 0AL15 0AA0 Standard 6GK6015 0AL15 0AA1 Conformal Coated RUGGEDCOM RX1500PN PS HI shipped until 2019 Specifications Input Range 88 to 300 VDC or 85 to 264 VAC Terminal Type Non re movable Screw Article Numbers 6GK6015 0AL13 0AA0 Standard 6GK6015 0AL13 0AA1 Conformal Coated RUGGEDCOM RX1500PN PS HI shipped from 2019 on Specifications Input Range 88 to 300 VDC ...

Page 38: ...ed Distance 100 m 328 ft Power Consumption 4 W Article Numbers 6GK6015 0AL20 0PB0 Standard 6GK6015 0AL20 0PB1 Conformal Coated RUGGEDCOM RX1500PN LM CG03B Specifications Ports 2 Speed 1000 Mbps Interface TX Port Type M12 8 Pin A Coded Controlled By pass Distance 100 m 328 ft Power Consumption 4 W Article Numbers 6GK6015 0AL20 0PE0 Standard 6GK6015 0AL20 0PE1 Conformal Coated RUGGEDCOM RX1500PN LM ...

Page 39: ...ed 100 Mbps Interface TX Port Type M12 8 Pin A Coded Controlled By pass Distance 100 m 328 ft Power Consumption 5 W Article Numbers 6GK6015 0AL20 0PF0 Standard 6GK6015 0AL20 0PF1 Conformal Coated RUGGEDCOM RX1500PN LM 4TX04 Specifications Ports 4 Speed 100 Mbps Interface TX Port Type M12 4 Pin D Coded Distance 100 m 328 ft Power Consumption 5 W Article Numbers 6GK6015 0AL20 0PD0 Standard 6GK6015 0...

Page 40: ...dard 6GK6015 0AL20 0BC1 Conformal Coated RUGGEDCOM RX1500PN LM FL01 Specifications Mode MM Speed 10 100 Mbps Interface FL SX Wavelength 820 nm Ports 3 Port Type ST Distance 2 km 1 2 mi Power Consumption 5 W Article Numbers 6GK6015 0AL20 0BD0 Standard 6GK6015 0AL20 0BD1 Conformal Coated RUGGEDCOM RX1500PN LM FG03 Specifications Mode SM Speed 1000 Mbps Interface LX Wavelength 820 nm Ports 4 Port Typ...

Page 41: ...COM RX1500PN LM FX51 Specifications Mode SM Speed 100 Mbps Interface FX Wavelength 1310 nm Ports 2 Port Type LC Distance 2 km 1 2 mi Power Consumption 5 W Article Numbers 6GK6015 0AL20 0BJ0 Standard 6GK6015 0AL20 0BJ1 Conformal Coated RUGGEDCOM RX1500PN LM 6FX50 Specifications SFP Sockets 6 Speed 100 Mbps Power Consumption 7 W Article Numbers 6GK6015 0AL20 0JD0 Standard 6GK6015 0AL20 0JD1 Conforma...

Page 42: ...s 6GK6015 0AL20 0MC0 Standard 6GK6015 0AL20 0MC1 Conformal Coated RUGGEDCOM RX1500PN LM TC4 Specifications Interface T1 E1 Ports 4 Port Type RJ48C Power Consumption 3 W Article Numbers 6GK6015 0AL20 0MD0 Standard 6GK6015 0AL20 0MD1 Conformal Coated RUGGEDCOM RX1500PN LM E02 Specifications Interface E1 Ports 2 Port Type BNC 75 Ω Power Consumption 3 W Article Numbers 6GK6015 0AL20 0HC0 Standard 6GK6...

Page 43: ...ity Se condary SIM Dual Mini SIM 2FF Power Consumption 7 W Article Numbers 6GK6015 0AL20 0WC0 Standard 6GK6015 0AL20 0WC1 Conformal Coated RUGGEDCOM RX1500PN LM W21 Specifications Services EVDO Rev A Region North America Verizon Port Type 50 Ω SMA Antennas 1 x EVDO Rev A 1 x Receive Diversity Secondary SIM Dual Mini SIM 2FF Power Consumption 7 W Article Numbers 6GK6015 0AL20 0WD0 Standard 6GK6015 ...

Page 44: ...DC HSPA UMTS WC DAM EDGE GPRS GSM GNSS Region European Union Port Type 50 Ω SMA Antennas 1 x LTE Main 1 x LTE MIMO 1 x GPS SIM Dual Mini SIM 2FF Power Consumption 7 W Article Numbers 6GK6015 0AL20 0WG0 Standard 6GK6015 0AL20 0WG1 Conformal Coated RUGGEDCOM RX1500PN LM W51 Specifications Services 4G LTE HSPA HSDPA HSUPA DC HSAP UMTS WDCAM EDGE GPRS GSM CDMA EV DO GNSS Region North Ameri ca AT T Rog...

Page 45: ...ption 7 W Article Numbers 6GK60150AL200WK0 Standard 6GK60150AL200WK1 Conformal Coated RUGGEDCOM APE Modules RUGGEDCOM RX1500PN LM APE1402 Obso lete Specifications Operating System De bian Linux Processor Intel Atom E660 1 3 GHz 512 KB L2 Cache RAM 2 GB DDR2 800 MHz 32 bit Disk 8 GB SATA Solid State Networking Realtek RTL8111 RJ45 Gigabit Ethernet Interface USB 2 x USB 2 0 a Video Intel 4108 Graphi...

Page 46: ...GB DDR2 800 MHz 32 bit Disk 16 GB SATA Solid State Networking Realtek RTL8111 RJ45 Gigabit Ethernet Interface USB 2 x USB 2 0 a Video Intel 4108 Graphics Processor DVI D Power Consumption 10 W Article Numbers 6GK6015 0AL20 0GD0 Standard 6GK6015 0AL20 0GD1 Conformal Coated RUGGEDCOM RX1500PN LM APE1404 ADM Ob solete Specifications Operating System Debian Linux and CROSSBOW ADM Processor Intel Atom ...

Page 47: ... Numbers 6GK6015 0AL20 0GE0 Standard 6GK6015 0AL20 0GE1 Conformal Coated RUGGEDCOM RX1500PN LM APE1404CKP Ob solete Specifications Operating System Check Point GAiA OS Processor Intel Atom E660T 1 3 GHz 512 KB L2 Cache RAM 2 GB DDR2 800 MHz 32 bit Disk 16 GB SATA Solid State Networking Realtek RTL8111 RJ45 Gigabit Ethernet Interface USB 2 x USB 2 0 a Video Intel 4108 Graphics Processor DVI D Power...

Page 48: ... bit Disk 64 GB Solid State Networking Intel I210 RJ45 Gigabit Ethernet Interface USB 2 x USB 3 0 Video Intel HD Graphics Processor Display Port Power Consumption 12 W Article Numbers 6GK6015 0AL20 0GJ0 Standard 6GK6015 0AL20 0GJ1 Conformal Coated a Maximum combined USB device power consumption is 500 mA at 5 V Blank Modules RUGGEDCOM RX1500PN PS XXP Specifications Article Numbers 6GK6015 0AL10 0A...

Page 49: ...dules by the chassis If the total power consumption exceeds this value power fluctuations and irregular shut downs may occur For the maximum power consumption of each line module refer to Available Mod ules Page 26 IMPORTANT Only one WAN line module is supported per chassis NOTICE Contamination hazard risk of equipment damage Prevent the ingress of water dirts and other debris that may lead to pre...

Page 50: ...ack Installing a Module To install a line module do the following 1 Optional If the device is installed in a rack remove it from the rack 2 Remove the current module from the slot 3 Insert the new module into the slot 1 2 3 1 Module 2 Chassis 3 Screw Figure 4 3 Installing a Module 4 Tighten the screws to secure the module 5 Optional If necessary install the device in the rack RUGGEDCOM RX1501 Inst...

Page 51: ...s that may lead to premature equipment failure Always make sure slots are not left empty Removing a Power Module To remove a power module do the following DANGER Electrocution hazard risk of serious personal injury or death Make sure power to the module is turned off before servicing the power supply ter minal 1 Turn off power to the module 42 RUGGEDCOM RX1501 Installation Manual 05 2020 C79000 G8...

Page 52: ... and set it aside to be connected later to the new module 5 Install a new or blank module to prevent the ingress of dust and dirt Installing a Power Module To install a power module do the following 1 If equipped remove the existing module 2 If applicable connect the supplied terminal block to the module or connect the terminal block from the previous module 3 Confirm or connect the wiring from th...

Page 53: ...ws to secure the power module to the chassis 6 Turn on power to the device and confirm the module is receiving and supplying power This is indicated by the LEDs on the module LED State Description O Green The module is supplying power I Green The module is receiving power 44 RUGGEDCOM RX1501 Installation Manual 05 2020 C79000 G8976 1054 17 All manuals and user guides at all guides com ...

Page 54: ... VAC 3 15 A T b 65 W 2800 VDC for 1 minute 24 24P 13 VDC 36 VDC 10 A T b 63 5 W 48 48P 36 VDC 72 VDC 3 15 A T b 60 W 1500 VDC for 1 minute 12 12P 9 VDC 15 VDC 12 A 67 W 1500 VAC or 2121 VDC for 1 minute a Power consumption varies based on the device configuration b T denotes time delay fuse 5 2 Failsafe Relay Specifications Maximum Switching Voltage Rated Switching Current Isolation 30 VDC 5 A 125...

Page 55: ... to 85 C 40 to 185 F Ambient Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity c 5 to 95 Maximum Altitude 12192 m 40000 ft a Measured from a 30 cm 12 in radius surrounding the center of the enclosure b Operating temperature may vary based on the limitations of installed SFPs Refer to the RUGGEDCOM SFP Transceivers Catalog for SFP temperature ratings c Non condensing 5 4 Mechanic...

Page 56: ...ications 5 5 Dimension Drawings 440 9 296 7 44 2 Figure 5 1 Overall Dimensions RUGGEDCOM RX1501 Installation Manual 05 2020 C79000 G8976 1054 17 47 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 57: ... 4 7 6 35 463 8 31 8 Figure 5 2 Rack Mount Dimensions 160 0 489 2 51 6 479 0 134 6 68 8 21 1 11 7 29 0 51 1 161 0 212 1 Figure 5 3 Panel and Din Rail Mount Dimensions 48 RUGGEDCOM RX1501 Installation Manual 05 2020 C79000 G8976 1054 17 All manuals and user guides at all guides com ...

Page 58: ...ngs 19 7 151 4 102 9 113 3 162 5 Figure 5 4 Line Module Dimensions 162 5 40 6 151 8 102 9 113 4 Figure 5 5 Power Module Dimensions RUGGEDCOM RX1501 Installation Manual 05 2020 C79000 G8976 1054 17 49 All manuals and user guides at all guides com ...

Page 59: ...Technical Specifications 5 5 Dimension Drawings 50 RUGGEDCOM RX1501 Installation Manual 05 2020 C79000 G8976 1054 17 All manuals and user guides at all guides com ...

Page 60: ...ollowing standards CAN CSA C22 2 NO 60950 1 07 R2012 Information Technology Equipment Safety Part 1 General Requirements Bi National standard with UL 60950 1 UL 60950 1 Information Technology Equipment Safety Part 1 General Requirements Certification is filed under E361664 6 1 2 TÜV SÜD This device is certified by TÜV SÜD to meet the requirements of the following stan dards CAN CSA C22 2 NO 60950 ...

Page 61: ...evance Directive 1999 5 EC Directive 1999 5 EC of the European Parliament and of the Council of 9 March 1999 on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity EN 60950 1 Information Technology Equipment Safety Part 1 General Requirements EN 61000 3 2 Electromagnetic compatibility EMC Part 3 2 Limits Limits for harmonic cur rent emissions eq...

Page 62: ...if not in stalled and used in accordance with the instruction manual may cause harmful inter ference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense IMPORTANT Changes or modifications not expressly approved by the party responsible for com pliance ...

Page 63: ... of Conformity is available via Siemens Industry Online Sup port at https support industry siemens com cs ww en view 89855782 6 1 8 RoHS This device is declared by Siemens AG to meet the requirements of the following Ro HS Restriction of Hazardous Substances directives for the restricted use of certain hazardous substances in electrical and electronic equipment China RoHS 2 Administrative Measure ...

Page 64: ... Line 4 DC Power Ports 2 kV Line to Ground 1 kV Line to Line 3 IEC 61000 4 5 Surge AC Power Ports 4 kV Line to Ground 2 kV Line to Line 4 Signal ports DC Power Ports AC Power Ports IEC 61000 4 6 Induced Con ducted RFI Earth ground ports 10 V 3 100 A m continuous 1000 A m for 1 s Note a IEC 61000 4 8 Magnetic Field Enclosure Ports 1000 A m for 1 s 5 IEC 61000 4 11 Voltage Dips and Interrupts AC Pow...

Page 65: ...hile Class 2 requires error free and interrupted communications Description Test Levels Signal ports 5 kV Failsafe Relay Output DC Power Ports HV Impulse AC Power Ports 5 kV Signal ports 2 kV DC Power Ports 1 5 kV Dielectric Strength AC Power Ports 2 kV Signal ports 4 kV 2 5 kHz DC Power Ports AC Power Ports Fast Transient Earth ground ports 4 kV Signal ports 2 5 kV common mode 1MHz DC Power Ports...

Page 66: ...1 1 Vibration 2 g 10 150 Hz Class 2 Shock 30 g 11 ms Class 2 IEC 60255 21 2 Bump 10 g 16 ms Class 1 Long Life Random Vibration IEC 61373 Shock Category 1 Class B IEC 60255 21 3 Seismic Method A Level 2 MIL STD 810G Altitude 12192 m 40000 ft 40 C 90 minutes RUGGEDCOM RX1501 Installation Manual 05 2020 C79000 G8976 1054 17 57 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 67: ...Certification 6 2 EMC and Environmental Type Tests 58 RUGGEDCOM RX1501 Installation Manual 05 2020 C79000 G8976 1054 17 All manuals and user guides at all guides com ...

Page 68: ...ggedcom Industry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY All manuals and user guides at all guides com ...

Reviews: