Certification
6.2 EMC and Environmental Type Tests
Test
Description
Test Levels
Severity
Levels
60% for 5 Cycles
100% for 250 Cycles
Signal Ports
30 V Continuous
300 V for 1 s
4
IEC
61000-4-16
Mains Frequency Voltage
DC Power
Ports
30 V Continuous
300 V for 1 s
4
IEC
61000-4-17
Ripple on DC Power Supply
DC Power
Ports
15%
4
IEC
61000-4-18
Damped Oscillatory Wave
Slow
Damped
2.5 kV Common
100 kHz or 1 MHz
3
IEC
61000-4-29
Voltage Dips and Interrupts
DC Power
Ports
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
Signal Ports 2 kV (Failsafe Relay Output)
DC Power
Ports
2 kV or 2.8kV DC
Dielectric Strength
AC Power
Ports
2 kV
Signal Ports 5 kV (Failsafe Relay Output)
DC Power
Ports
5 kV
IEC
60255-27
HV Impulse
AC Power
Ports
5 kV
EMC Immunity Type Tests per IEEE 1613
Note
RUGGEDCOM products meet Class 1 requirements for copper Ethernet
configurations and Class 2 for fiber Ethernet configurations. Class 1 allows for
temporary communication loss, while Class 2 requires error-free and interrupted
communications.
Test
Description
Test Levels
Enclosure Contact
± 8 kV
IEEE 1613
ESD
Enclosure Air
± 15 kV
IEEE 1613
Radiated RFI
Enclosure Ports
35 V/m
Signal Ports
± 4 kV @ 2.5 kHz, 5 kHz
DC Power Ports
± 4 kV @ 2.5 kHz, 5 kHz
AC Power Ports
± 4 kV @ 2.5 kHz, 5 kHz
IEEE 1613
Fast
Transient
Earth Ground Ports
± 4 kV
IEEE 1613
Oscillatory
Signal Ports
2.5 kV Common
Mode @ 1 MHz
RUGGEDCOM RSG908C
Installation Manual, 04/2022, C79000-G8976-1404-11
37