Certification
6.1.2 CSA/Sira
•
ANSI/UL 60079-15:13
Electrical Apparatus for Explosive Gas Atmospheres – Part 15: Type of Protection
"n"
The device is marked with a CSA symbol that indicates compliance with both
Canadian and U.S. requirements.
C
US
It is specifically approved for use in Division 2 and Zone 2 hazardous locations with
the following markings:
• Class I, Division 2, Groups A, B, C, D T4
• Ex nA nC IIC T4 Gc
• Class I, Zone 2, AEx nA nC IIC T4 Gc
This device meets the requirements of the following International standards under
certificate IECEx CSA 18.0007X:
•
IEC 60079-0:2011
Explosive Atmospheres – Part 0: Equipment – General Requirements
•
IEC 60079-15:2010
Electrical Apparatus for Explosive Gas Atmospheres – Part 15: Construction, Test
and Marking of Type of Protection "n" Electrical Apparatus.
6.1.2
CSA/Sira
When marked with the following ATEX marking, this device is approved for use in
Zone 2 hazardous locations under certificate Sira 18ATEX4069X.
Note
For the maximum ambient temperature, refer to the hazardous location label affixed
to the device.
II 3 G Ex nA nC IIC T4 Gc
The device also meets the requirements of the following European directive and
standards:
•
2014/34/EU
Directive 2014/34/EU of the European Parliament and of the Council of 26
February 2014 on the harmonisation of the laws of the Member States relating
to equipment and protective systems intended for use in potentially explosive
atmospheres (recast) Text with EEA relevance
32
RUGGEDCOM RSG908C
Installation Manual, 04/2022, C79000-G8976-1404-11