RUGGEDCOM RSG2300
Installation Guide
Chapter 4
Technical Specifications
Gigabit Ethernet (1 Gbps) Optical Specifications
33
Section 4.5.3
Gigabit Ethernet (1 Gbps) Optical Specifications
Fixed Gigabit Transceivers
NOTE
These transceivers utilize a distributed feedback (DFB) type laser and are rated for -20 to 85 °C (-4 to
185 °F) operation only.
Mode
Connector
Type
Cable
Type (µm)
v
Tx λ (nm)
w
Tx
Minimum
(dBm)
x
Tx
Maximum
(dBm)
x
Rx
Sensitivity
(dBm)
x
Rx
Saturation
(dBm)
x
Maximum
Distance
(km)
y
Power
Budget
(dB)
50/125
MM
LC
62.5/125
850
-9
-2.5
-20
0
0.5
11
SM
SC
9/125
1310
-10
-3
-20
-3
10
10
SM
LC
9/125
1310
-9.5
-3
-21
-3
10
11.5
SM
SC
9/125
1310
-5
0
-20
-3
25
15
SM
LC
9/125
1310
-7
-3
-24
-3
25
17
v
All cabling is duplex type unless specified otherwise.
w
Typical.
x
All optical power numbers are listed as dBm averages.
y
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens
sales associates when determining maximum segment distances.
SFP Gigabit Transceivers
NOTE
SFP transceivers have a temperature range of -40 to 85 °C (-40 to 185 °F), unless specified otherwise.
Mode
Connector
Type
Cable
Type (µm)
Tx λ (nm)
z
Tx
Minimum
(dBm)
aa
Tx
Maximum
(dBm)
aa
Rx
Sensitivity
(dBm)
aa
Rx
Saturation
(dBm)
aa
Maximum
Distance
(km)
ab
Power
Budget
(dB)
50/125
0.5
MM
ac
LC
62.5/125
850
-9
-2.5
-20
0
0.3
11
SM
LC
9/125
1310
-9.5
-3
-19
-3
10
9.5
SM
LC
9/125
1310
-7
-3
-23
-3
25
16
SM
ad
LC
9/125
1550
0
5
-23
-3
70
23
z
Typical.
aa
All optical power numbers are listed as dBm averages.
ab
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens
sales associates when determining maximum segment distances.
ac
Operating temperature range of -10 to 85 °C (14 to 185 °F).
Summary of Contents for RUGGEDCOM RSG2300
Page 4: ...RUGGEDCOM RSG2300 Installation Guide iv ...
Page 12: ...RUGGEDCOM RSG2300 Installation Guide Chapter 1 Introduction Description 4 ...
Page 36: ...RUGGEDCOM RSG2300 Installation Guide Chapter 3 Communication Ports BNC Ports 28 ...
Page 46: ...RUGGEDCOM RSG2300 Installation Guide Chapter 5 Dimension Drawings 38 ...