RS232 Console Port
Connect a PC or terminal directly to the RS232 console port to access the boot-time control and ROS interfaces.
The console port provides access to ROS's console and Web interfaces.
IMPORTANT!
The console port is intended to be used only as a temporary connection during initial configuration or
troubleshooting.
Connection to the console port is made using an RJ45-to-DB9 console cable. The following is the pin-out for the
console port:
1
8
Figure 14: RJ45 Console Port Pin Configuration
Pin
RJ45
Male
DB9
Female
Name
Description
Comment
1
6
DSR
a
Data Set Ready
2
1
DCD
a
Carrier Detect
Reserved (Do
Not Connect)
3
4
DTR
a
Data Terminal
Ready
4
5
GND
Signal Ground
5
2
RxD
Receive Data
(to DTE)
6
3
TxD
Transmit Data
(from DTE)
7
8
CTS
b
Clear to Send
8
7
RTS
b
Read to Send
1
9
RI
c
Ring Indicator
a
The DSR, DCD and DTR pins are connected together internally.
b
The CTS and RTS pins are connected together internally.
c
RI is not connected.
Communication Ports
Connect any of the available Ethernet ports on the device to a management switch and access the ROS console
and Web interfaces via the device's IP address. For more information about available ports, refer to
.
Section 2.6
Cabling Recommendations
Before connecting the device, be aware of the recommendations and considerations outlined in the following
sections:
•
Section 2.6.1, “Protection On Twisted-Pair Data Ports”
•
Section 2.6.2, “Gigabit Ethernet 1000Base-TX Cabling Recommendations”
Summary of Contents for RUGGEDCOM RSG2300
Page 4: ...RUGGEDCOM RSG2300 Installation Guide iv ...
Page 12: ...RUGGEDCOM RSG2300 Installation Guide Chapter 1 Introduction Description 4 ...
Page 36: ...RUGGEDCOM RSG2300 Installation Guide Chapter 3 Communication Ports BNC Ports 28 ...
Page 46: ...RUGGEDCOM RSG2300 Installation Guide Chapter 5 Dimension Drawings 38 ...