Description
• IP65 rated for protection against high pressure jets of water
• Hazardous location certification: Class 1 Division 2
• -40 to 85 °C (40 to 185 °F) operating temperature (no fans)
• Conformal coated circuit boards (optional)
• Failsafe output relay for critical failure or error alarming
Universal Power Supply Options
• Fully integrated power supply
• Universal high-voltage range: 88-300 VDC or 85-264 VAC.
• Popular low-voltage DC ranges: 12, 24, 48 VDC
• Dual redundant, parallel load-sharing power supplies (option)
• Can be powered from different sources for ultimate redundancy
• Available with M12 (Mini-Change) or M23 style connectors
• CSA/UL 60950-1 safety approved to 85 °C (185 °F)
Simple Plug and Play Operation
• Automatic learning of up to 8192 MAC addresses
• Auto-negotiation on all 10/100Base-TX ports, 100FX on optic fiber ports
• Auto-MDI/MDIX (crossover) on all 10/100Base-TX ports
• LED indicators for link and activity
Section 1.2
Description
The RUGGEDCOM RS969 features various ports, controls and indicator LEDs for connecting, configuring and
troubleshooting the device.