Chapter 2
Installing the Device
RUGGEDCOM RS969
Installation Guide
12
Connecting Power
2
1
4
3
Figure 5: Failsafe Alarm Relay Wiring
Pin
Description
1
Normally Closed
2
Common
3
Normally Open
Section 2.5
Connecting Power
The RUGGEDCOM RS969 is equipped with either a Mini or M23 A-coded male power supply input connector.
The Mini power connector only has four terminals, so only one power supply source is allowed to connect to the
RUGGEDCOM RS969 with the Mini power connector. The M23 power connector has five terminal pins, which
allows for two power supply sources to be connected to the RUGGEDCOM RS969 with the M23 power connector.
When equipped with an M23 power connector, the RUGGEDCOM RS969 supports dual redundant power supplies:
Power Supply 1 (PS1)
and
Power Supply 2 (PS2)
.
CONTENTS
•
Section 2.5.1, “Power Supply Connector Pin-Out”
•
Section 2.5.2, “Power Supply Wiring”
•
Section 2.5.3, “Disabling Line-to-Ground Transient Protection”
Section 2.5.1
Power Supply Connector Pin-Out
The following is the pin-out for the Mini and M23 A-coded power supply connector:
Summary of Contents for RUGGEDCOM RS969
Page 4: ...RUGGEDCOM RS969 Installation Guide iv ...
Page 10: ...Preface RUGGEDCOM RS969 Installation Guide x Customer Support ...
Page 18: ...Chapter 1 Introduction RUGGEDCOM RS969 Installation Guide 8 Decommissioning and Disposal ...
Page 40: ...Chapter 5 Technical Specifications RUGGEDCOM RS969 Installation Guide 30 Dimension Drawings ...