Chapter 2
Installing the Device
RUGGEDCOM MX5000RE
Installation Guide
18
Installing the EMI Gaskets
2
1
Figure 13: Mounting Brackets
1.
Mounting Bracket
2.
#10-32×1/2" Flat Head Hex Socket Screw
2. Secure the mounting bracket with 20 flat head hex socket screws. Hand tighten each screw and make sure
each screw head is flush with the surface of the mounting bracket.
3. Repeat
and
for the mounting bracket on the opposite side of the RUGGEDCOM MX5000.
Section 2.8
Installing the EMI Gaskets
The material for the EMI (Electro-Magnetic Interference) gaskets is provided in two lengths for the two different
sizes of patch panel openings in the RUGGEDCOM MX5000:
EMI Gasket Material Length
Patch Panel Opening
19.5"
D, E, F and G
35.5"
A, B, C, H, J and K
To install the EMI gaskets, do the following:
1. Make sure the groove surrounding each panel opening is free of dust, dirt or liquid.
2. Inspect each gasket for signs of twisting, cracking, wear or damage. If the gaskets need to be replaced, cut
and discard the them.
IMPORTANT!
• Do not stretch the gasket material. Stretching the gasket material will degrade performance. If
gasket material is inadvertently stretched, remove it from the patch panel groove and allow it to
sit for 8 hours before attempting to install it again. The material will return to its original length.
• Do not cut the gasket to length before assembly.