BA 5200 EN 08/2010
Faults
Remedy
Causes
Oil leakage from the gear unit.
Inadequate sealing of housing
covers and/or joints.
Radial shaftsealing rings defective.
Check and, if necessary,
replace sealings. Seal joints.
Check radial shaftsealing rings
and, if necessary, replace.
Oil foaming in the gear unit.
Preservation agent not completely
drained.
Oilsupply system has been
operated too long at low
temperatures.
Gear unit too cold in operation.
Water in oil.
Oil too old
(defoaming agent used up).
Unsuitable oils mixed up.
Oil change.
Stop oilsupply system.
Allow the oil to degas.
Shut down gear unit and have oil
degassed. Restart without cooling
water.
Test the oil, change oil if necessary.
Test the oil, change oil if necessary.
Test the oil, change oil if necessary.
Water in oil.
Oil foams in sump.
Defective oilsupply system or
cooling coil.
Gear unit exposed to cold air from
machineroom ventilator: Water
condensing.
Climatic conditions.
Check state of oil by the testtube
method for water contamination.
Have oil analysed by laboratory.
Check the oilsupply system or
cooling coil, replace any defective
parts. Consult operating instructions
for oilsupply system.
Protect gear unit with suitable heat
insulation. Close air outlet or alter its
direction by structural measures.
Contact Customer Service.
If necessary, fit wetair filter.
Increased operating
temperature.
Oil level in housing too high.
Oil too old.
Oil badly contaminated.
Defective oilsupply system or
cooling coil.
Check oil level and,
if necessary, adjust.
Check date of last oil change and,
if necessary, change oil.
See section 10.
Change oil. See section 10.
Check the oilsupply system or
cooling coil, replace any defective
parts. Consult operating instructions
for oilsupply system.
Fault in oilsupply system.
Consult operating instructions
for oilsupply system.