BA 5200 EN 08/2010
6.8
Gear unit with torque arm
•
Attaching the torque arm
The torque arm must be mounted stressfree.
•
Foundation type for fastening the torque arm, see item 6.3.1, "Foundation".
•
A detailed view of the gear unit can be obtained from the drawings in the gearunit documentation.
6.9
Gear unit with gearunit swing
•
Attach the support.
The support for the gearunit swing base must be mounted free of stress.
•
Foundation type for fastening the torque arm, see item 6.3.1, "Foundation".
•
A detailed view of the gear unit can be obtained from the drawings in the gearunit documentation.
6.10
Gear units with cooling coil
•
Before connecting the cooling coil the screw plugs must be removed from the connecting bushes.
•
Flush the cooling coil (in order to remove any contamination).
•
Connect the coolingwater in and outflow pipes (for exact position of the connections, see
dimensioned drawing).
Observe also item 5.7.2.
6.11
Gear units with addon air oilcooler
•
Connect pressure monitor electrically.
•
Connect contamination indicator of the double changeover filter (if fitted) electrically.
•
Connect the fan motor electrically.
6.12
Gear units with add‐on water oilcooler
•
Before connecting the water oilcooler remove the sockets from the coolingwater connections.
•
Flush the water oilcooler (in order to remove any contamination).
•
Install the coolingwater in and outflow pipes (for flow direction and exact position of connections, see
dimensioned drawing).
Make sure when installing the piping that no forces, moments or vibrations act upon
the connections of the water oilcooler.
•
Wire the pressure monitor electrically (in case of gear units with corresponding equipment only).
Observe also item 5.7.3.
For connecting dimensions, refer to the dimensioned drawing of the gear unit. The required
cooling water quantity and the max. permissible inlet temperature are given on the data sheet
and/or the list of equipment.