Technical Instructions 

QFA1000, QFA1001 Room Hygrostats 

Document Number 155-708 
July 19, 2010 

Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as 
design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners. 
© 2010 Siemens Industry, Inc. 

 

Siemens Industry, Inc. 

Building Technologies Division 
1000 Deerfield Parkway 
Buffalo Grove, IL  60089-4513 
U.S.A. 

Your feedback is important to us. If you have 
comments about this document, please send them 
to 

[email protected]

 

Materials and colors 

Base 

 

PPS, Fortron, fiberglass reinforced, 

   

Black 

Cover   

PC Lexan 940, pure-white 

Humidity measuring element 

Plastic  

Standards 

 conformity 

EMC directive 

89/336/EEC 

UL  

UL873 

cUL 

Canadian Standard C22.2 No. 24-93 

Weight 

QFA1001 

3.17 ounces (0.090 kg) 

QFA1000 

3.17 ounces (0.090 kg) 

Wiring Diagrams 

Internal Diagram 

 

 
 

1-2 Humidification 
1-3 Dehumidification 

Wiring Diagrams 

 

Figure 3. Humidification. 

 

Figure 4.  Dehumidification. 

Dimensions 

Figure 5.  Dimensions in Inches (Millimeters). 

 

 

Document No. 155-708 

Printed in the U.S.A. 

Page 4 

 

Summary of Contents for QFA1000

Page 1: ...midity measuring element made of stabilized plastic Setpoint knob for the upper switching point Mounts directly on the wall or on a recessed conduit box Application For controlling humidification equipment For controlling dehumidification equipment Product Numbers Switching Differential 1 Product Number Setpoint Setting Range Statically Dynamically Setpoint Adjustment QFA1000 Internally QFA1001 30...

Page 2: ...g effect the switching point drifts slowly and constantly For this reason recalibration may be required in due time At temperatures other than the calibration temperature the switching point drifts systematically temperature influence Also in the case of fast humidity changes the switching point will temporarily be shifted Mechanical Design QFA1001 The room hygrostat is designed for wall mounting ...

Page 3: ...all Sources of heat and refrigeration radiators computers televisions concealed heating pipes hot or cold water pipes must be at an adequate distance The hygrostat should not be exposed to direct sunlight Mounting Instructions Installation Instructions for the room hygrostat are available online Specifications Functional data Setpoint range 30 to 90 rh Temperature operating range 32 F to 122 F 0 C...

Page 4: ...IL 60089 4513 U S A Your feedback is important to us If you have comments about this document please send them to SBT_technical editor us sbt siemens com Materials and colors Base PPS Fortron fiberglass reinforced Black Cover PC Lexan 940 pure white Humidity measuring element Plastic Standards conformity EMC directive 89 336 EEC UL UL873 cUL Canadian Standard C22 2 No 24 93 Weight QFA1001 3 17 oun...

Reviews: