2/7 

Siemens 

Master room unit QAX850 

 

CE1N2722en 

Building Technologies  

 

28.08.2007 

Type summary 

Type reference 

Description  

Compatible with* 

QAX850 

Master room unit 

 Temperature controller RRV851 

  Temperature controller RRV852  

 Temperature controller RRV856 

  Zone room unit QAW850 

* Not usable with Desigo RX range of controllers  

Product documentation 

Document  

Document number 

Data sheet 

N2722 

Mounting instructions 

M2721 

Operating instructions for use with RRV81 

B2725en01 

Operating instructions for use with RRV82 

B2726en01 

Operating instructions for use with RRV82 (duo-switch) 

B2726en03 

Operating instructions for use with RRV86 

B2727en01 

Declaration of conformity

 

T2722

 

Mechanical design 

The QAX850 is the installer/OEM/end-user master MMI for RRV controllers. 

 

The unit consists of the following components: 

  Room unit with integrated electronics and operating elements 

  Internal temperature sensor 

  Base for wall mounting with the connection terminals 

  Operator interface buttons (high use) 

  Operator interface buttons behind door (low use) 

 

272

2P

01

1

2

3

4

5

6

7
8
9
10
11

 

LED for heat/cool output status 

LCD display with EL backlight for control and monitoring of modes,  
setpoints, zone conditions etc 

Operating mode selection – Comfort, energy saving and auto timer  
(RRV852 Day/Night zone selection for Duo-zone application) 

Temporary setpoint and value increase/decrease 

System off and fan speed control 

Heat, cool, heat/cool changeover and ventilation only selection 

Time and weekday setting 

Auto timer schedule setting 

Zone output selection (RRV856 and RRV852 for Duo-switch application) 

10 

Permanent comfort and energy saving setpoints (Day/Night/Both setpoints  
for RRV852 Duo-zone application)  

11 

Button for confirming values and scrolling through parameter sets 

Components 

Operating elements 

Summary of Contents for QAX850

Page 1: ...n air based plants including heating cooling and ventilation HVAC equipment Suitable for Standard Duo zone Duo switch and Multi zone applications Functions Remote control and monitoring of an RRV controller Parameter adjustments by installer Room temperature measurement Time clock operation Comfort temperature setpoint adjustment Energy saving temperature setpoints adjustment Auto timer selection ...

Page 2: ...nents Room unit with integrated electronics and operating elements Internal temperature sensor Base for wall mounting with the connection terminals Operator interface buttons high use Operator interface buttons behind door low use 2722P01 1 2 3 4 5 6 7 8 9 10 11 1 LED for heat cool output status 2 LCD display with EL backlight for control and monitoring of modes setpoints zone conditions etc 3 Ope...

Page 3: ...e actual temperature measured with a certified thermometer Calibration function can be accessed by pressing the and buttons simultaneously for 5 seconds Displayed value can then be adjusted via the same buttons in 0 1K steps Range is 3 K Initial application set up of RRV controller to match the connected HVAC equipment is made by the selection of dip switch positions Dip switches are located on th...

Page 4: ...esistor sensor QAA32 or QAH11 to the RRV controller B1 input In this case the QAX850 automatically recognizes and displays the external sensor value Mounting and installation notes The QAX850 should be mounted in a location where the air temperature can be measured as accurately as possible without getting adversely affected by direct solar radiation or other heating or cooling sources There is no...

Page 5: ... HB Connection terminals For wires screw terminals 0 6 mm dia 2 5 mm2 Degrees of protection Degree of protection of housing to IEC 60 529 IP 30 Safety class to EN 60 730 device suited for use with equipment of safety class II Environmental conditions Operation to Climate conditions Temperature housing and electronics Humidity Mechanical conditions IEC 721 3 3 class 3K5 0 50 C 5 95 r h non condensi...

Page 6: ...1 Measuring range 0 49 C Room temperature measurement Setpoint range 5 35 C Accuracy at 20 C max 0 5 K Temperature calibration range max 3 0 K in increments of 0 5 K Room temperature display resolution 0 5 K Weight Excluding packaging approx 0 1 kg Notes The products may only be used in building services plant and applications as described above When using the products all requirements specified u...

Page 7: ... room unit QAX850 CE1N2722en Building Technologies 28 08 2007 Dimensions Room unit 96 119 23 8 3031M01 Base 89 45 4 3031M02 28 28 28 28 26 30 35 30 11 8 112 3 4 Dimensions in mm 2005 Siemens Switzerland Ltd HVAC Products ...