Operating Manual
U42093-J-Z716-1-74
Mounting the PSFR-CP41 in a Rack
Installing the PSFR-CP41
Fibre Channel connection
SCSI Connection
The PSFR-CP41 supports Fast/Ultra Wide SCSI. The PSFR-CP41 is factory
configured to support Differential SCSI bus. Two 68-pin D-shell connectors are
located on the rear panel of the unit, allowing the unit to be attached in the
middle or at the end of a SCSI bus. If the PSFR-CP41 is located at one end of
the SCSI bus, an external terminator should be installed. A terminator is
provided with the PSFR-CP41.
The PSFR-CP41 supplies termination power (TERMPWR) on the SCSI bus. A
self-resetting fuse is used that will reset after the fault is cleared.
Fig. “Fibre Channel connection”
shows the Fibre Channel port on the
back of the PSFR-CP41.
S CS I
DIFF
Differential SCSI support is indicated by this symbol on the
rear of the 6100.