OP1S Operator Control Panel
Siemens AG
477 459 4070 72 J AA-6R
SIMOVERT MASTERDRIVES
Operating Instructions
7
3 Operator control
3.1 Operator control elements
Key
Meaning
Function
ON key
•
For energizing the drive (enabling motor activation). This
function must be enabled by means of parameterization.
OFF key
•
For de-energizing the drive by means of OFF1, OFF2 or
OFF3, depending on parameterization. This function must
be enabled by means of parameterization.
Jog key
•
For jogging with jog setpoint 1 (only effective when the unit
is in the "ready to start" state). This function must be
enabled by means of parameterization.
Reversing
key
•
For reversing the direction of rotation of the drive. This
function must be enabled by means of parameterization.
Toggle key
•
For selecting menu levels and switching between
parameter number, parameter index and parameter value
in the sequence indicated. The current level is displayed by
the position of the cursor on the LCD display (the
command comes into effect when the key is released).
•
For concluding a numerical input
Reset
Reset key
•
For leaving menu levels
•
If fault display active, this is for acknowledging the fault.
This function must be enabled by means of
parameterization.
Raise key
For increasing the displayed value
•
Short press = single-step increase
•
Long press = rapid increase
•
If motor potentiometer is active, this is for raising the
setpoint. This function must be enabled by means of
parameterization.
Lower key
For lowering the displayed value
•
Short press = single-step decrease
•
Long-press = rapid decrease
•
If motor potentiometer is active, this is for lowering the
setpoint. This function must be enabled by means of
parameterization.