3.6 OP: Download
With the "OP: Download" function, a parameter set stored in the OP1S can be written
into the connected slave. Parameters of a possibly inserted technology board are not
taken into account (e.g. T100, T300). The SIMOVIS program is required here. Starting
from the basic menu, the "OP: Download" function is selected with "Lower" or "Raise"
and activated with "P".
Ê
Ê
P
Ì
Ì
MotionControl
*Menu selection
OP: Upread
#OP: Download
Download
*1909199701
MASTERDRIVES MC
PLUS
Example: Selecting and activating the
"Download" function.
One of the parameter sets stored in the OP1S must now be selected with "Raise" or
"Lower" (displayed in the second line). The selected ID is confirmed with "P". The slave
ID can now be displayed with "Raise" or "Lower" (see section "Slave ID"). The
"Download" procedure is then started with "P". During download, the OP1S displays the
currently written parameters.
Ê
Ê
P
Ì
Ì
Ê
Ê
P
Ì
Ì
Download
*1909199701
MASTERDRIVES MC
PLUS
Download
1909199701
MASTERDRIVES MC
PLUS
MotionControl 00
Download
Pxxx
Example: Confirming the ID
and starting the "Download"
procedure
With "Reset", the procedure can be stopped at any time. If downloading has been fully
completed, the message "Download ok" appears and the display returns to the basic
menu.
After the data set to be downloaded has been selected, if the identification of the stored
data set does not agree with the identification of the connected unit, an error message
appears for approximately 2 seconds. The operator is then asked if downloading is to be
discontinued.
Ê
Ê
P
Ì
Ì
Ê
Ê
P
Ì
Ì
Ê
Ê
2 s
Ì
Ì
Download
*1909199701
MASTERDRIVES MC
PLUS
Download
1909199701
MASTERDRIVES MC
PLUS
Error:
Different
IDs
MotionControl 00
•Stop download?
#yes
no
♦
Yes: Downloading is discontinued.
♦
No:
Downloading is carried out.