BA 2510
A5E38121849A/RS-AB, 10/2016
7
2.3
Maintenance of the output-side bearing in the agitator flange
Note
Change the grease filling of the roller bearing when you change the gearbox oil.
For refilling, use lithium-saponified roller bearing grease NLGI 3/2.
Procedure
1.
Dismantle the output-side bearing unit.
2.
Clean the bearing.
3.
Fill the bearing with the new grease up to approximately 30 % of the free bearing chamber.
4.
Reassemble the bearing unit.
Maintenance interval after regreasing
After regreasing, the maintenance interval can be increased to the following number of operating hours.
Table 2-3
Maintenance interval in operating hours after regreasing the agitator flange
Output speed n
2
Operating hours for size
68
88
108
128
148
168
[rpm]
[h]
≤ 30
80 000
80 000
80 000
80 000
80 000
50 000
31 … 50
80 000
80 000
80 000
80 000
40 000
40 000
51 … 100
80 000
80 000
45 000
45 000
28 000
28 000
101 … 150
80 000
80 000
40 000
32 000
25 000
20 000
151 … 250
50 000
45 000
28 000
25 000
15 000
15 000
251 … 400
40 000
32 000
20 000
20 000
10 000
10 000
3
Mixer flange
For bevel helical gearbox K.M and parallel shaft gearbox FD.M/FZ.M sizes 88 to 168
3.1
Technical description
①
Greased bearing
Figure 3-1
Bearing in mixer flange