Electrical Connections
Rotating the connector at the motor
1FK7 Synchronous Motors
2-2
Configuration Manual (PFK7), 10/2005 Edition, 6SN1197-0AD06-0BP1
2.2
Rotating the connector at the motor
Power connectors and signal connectors can be rotated to a limited extent.
Direction and torque when rotating
Fig. 2-2
Rotating a connector using an 1FK706 motor as an example
Notice
The permissible range of rotation may not be exceeded.
In order to guarantee the degree of protection, a max. 10 revolutions are permissible.
Do not exceed max. torque when rotating connectors.
Connectors should be rotated using the mating connector that matches the connector thread.
Connecting cables should be secured against strain and bending.
Motor connectors should be secured so that they cannot be rotated any further.
Connectors may not be subject to continuous force.
Table 2-1:
Direction and torque when rotating connectors
Power connector
Size 1
Power connector
Size 1.5
Signal connector
Clockwise direction of rotation [degrees]
270°
270°
90°
Counter-clockwise direction of rotation [degrees] Not possible
Not possible
180° for SH 28 to 80
90° for SH 100
Max. torque when rotating [Nm]
8
15
8