6

Installation Instructions

Before installation

Gas hobs

Load of one hotplate         max. 

0

3.9 kW

Load of all hotplates           max. 11.3 kW

Gas ceramic hob

The specifications for nominal heat load
do not apply to closed gas ceramic
hobs.
Always comply with the specifications of
the hotplate manufacturer.

The smaller the distance between the

extractor hood and hotplates, the greater
the likelihood that rising water vapour will
condense under the extractor hood.

The extractor hood may only be 

installed over a fireplace which burns solid
fuel (fire hazard due to flying sparks) if the
fireplace has a 

closed, non-detachable

cover

and national regulations have been

observed. This restriction does not apply
to gas cookers and gas hobs.

Exhaust-air mode. 

Fig. 6

The exhaust air is conducted upwards via a
ventilation shaft or directly through the 
outside wall into the atmosphere.

D

The exhaust air must not be conveyed

into a functioning smoke flue or exhaust-
gas flue or into a shaft which vents a room
with a fireplace.

Conveyance of exhaust air in a non-func-
tioning smoke flue or exhaust-gas flue
requires the prior consent of an appropriate
heating engineer.

D

If the extractor hood is in exhaust-air

mode and a flue-type heater is running
at the same time 

(e.g. gas, oil or solid-fuel

heaters, continuous-flow heaters, water
heaters),

ensure that the fireplace has an

adequate air supply 

for combustion.

Before reading these instructions, 

please fold out the illustrated back pages.

Important information:

Old appliances are not worthless 

rubbish. Valuable raw materials can be 
reclaimed by recycling old appliances.
Before disposing of your old appliance,
render it unusable.

You received your new appliance in a

protective shipping carton. All packaging
materials are environmentally friendly and
recyclable. Please contribute to a better
environment by disposing of packaging
materials in an environmentally-friendly
manner.

Please ask your dealer or inquire at your
local authority about current means of 
disposal.

The extractor hood can be used in

exhaust-air or circulating-air mode.

Always attach the extractor hood 

centred above the hotplates.

Minimum distance between hotplates

and lower edge of the extractor 
hood: 

650 mm.

Additional information for gas 
cooking appliances:

Comply with the currently valid 

installation regulations and the installation
instructions supplied by the gas appliance
manufacturers.

The extractor hood may be installed

with only one side next to a high-sided unit
or a high wall. Min. gap 50 mm.

The extractor hood must be installed at

a minimum distance of

650 mm above

gas hotplates 

– Fig. 5  – provided the fol-

lowing nominal heat loads (Hs) are not
exceeded:

Gas cookers

Load of one hotplate         max. 

0

3.0 kW

Load of all hotplates           max. 

0

8.3 kW

Load of oven                  

max. 

0

3.9 kW

56080 Int  10-01-2003  11:00  Pagina 6

Summary of Contents for LU13 series

Page 1: ...Operating Instructions Installation Instructions LU13 LU22 ...

Page 2: ......

Page 3: ...yed back into the kitchen The grease filter absorbs the grease particles in the kitchen vapours The activated carbon filter binds the odorous substances If the extractor hood is switched from exhaust air mode to circulating air mode the exhaust air opening must be sealed to prevent a hazardous situation see optional accessories in the Instructions for use Important information This extractor hood ...

Page 4: ...never be left unattended Do not flambé under the extractor hood Risk of grease filter catching fire catching fire from rising flames Certain restrictions apply if the extrac tor hood is to be installed over a fireplace which burns solid fuel coal wood etc see Installation instructions Always use gas hotplates correctly Important The flames of the gas hotplates must always be covered with a cooking...

Page 5: ...s of the filter grille Fig 1 1 2 Remove the filter grille Fig 1 2 3 Remove the wire grille and the saturated filter mat Fig 2 4 Clean the filter grille and insert a new filter mat Fig 2 5 Clamp the filter mat with the wire grille Fig 2 6 Re insert the filter grille Fig 1 2 The interlocks must lock into position on the left and right sides Fig 1 1 Metal grease filter The filter mats consist of non ...

Page 6: ... the filter grille Fig 1 1 2 Remove the filter grille Fig 1 2 3 Insert the activated carbon filter from below into the extractor hood housing and lock into position and turned clockwi se fig 3 4 Re insert the filter grille Fig 1 2 The interlocks must lock into position on the left and right sides Fig 1 1 Removing The activated carbon filter is removed in reverse sequence Replacing the activated ca...

Page 7: ...tainless steel cleaning agent Stainless steel surfaces Use a mild non abrasive stainless steel cleaning agent Clean only in the direction of the ground surface Do not clean stainless steel surfaces with scouring sponges or with cleaning agents containing sand soda acid or chlorides Replacing the lamps 1 Switch off the extractor hood and isolate the extractor hood by pulling out the mains plug or s...

Page 8: ...tinuous flow heaters water heaters ensure that the fireplace has an adequate air supply for combustion Before reading these instructions please fold out the illustrated back pages Important information Old appliances are not worthless rubbish Valuable raw materials can be reclaimed by recycling old appliances Before disposing of your old appliance render it unusable You received your new appliance...

Page 9: ...r mode with activated carbon filter there are no operating restrictions If the exhaust air is conveyed through the exterior wall a telescopic wall box should be used Fig 7 Connection options between the extractor hood and telescopic wall box Exhaust air hose or exhaust air pipe Direct connection Optimum performance of the extractor hood Short smooth exhaust air pipe Minimum number of pipe bends La...

Page 10: ...on cable must be replaced by the manufacturer or his customer service or a similarly qualified person If a permanent connection is required The extractor hood may be connected only by an electrical engineer who is registered at the relevant electricity supply company A disconnecting device must be fitted on the installation side Switches with a contact gap of more than 3 mm and all pole disconnect...

Page 11: ...erfect hori zontal level fig 11 1 adjust it by using the adjusting screws fig 11 2 7 Tighten the lower screw with washer inside the extractor hood Fig 12 To a wall hanging cupboard 60 cm wide extractor hood With 4 screws Fig 13 90 cm wide extractor hood With 4 screws Fig 13 1 Dimensions for the mounting boreholes can be found in Fig 13 or place a tem plate on the base of the wall hanging cupboard ...

Page 12: ...10 Notice ...

Page 13: ...11 Notice ...

Page 14: ...12 Notice ...

Page 15: ......

Page 16: ......

Page 17: ...Installation Instructions ...

Page 18: ......

Page 19: ......

Page 20: ...LIB0024982B Ed 07 15 BSH Ev Aletleri Sanayi ve Ticaret A Ş FSM Mah Balkan Cad 51 34771 Ümraniye İstanbul TURKEY www siemens home com ...

Reviews: