background image

9

Specifications

Weight in kg:

in accordance with DIN 44971

Exhaust air

Width

Circulating

air

60 cm

8,2

8,7

90 cm

Illuminance in lux:

110 Lux (2 x 40 Watt)

Design changes with respect to technical development
shall remain withheld.

9,7

10,2

Fitting the extractor hood

To the wall

60 cm 

wide extractor hood:

With 4 screws. Fig. 10.

90 cm 

wide extractor hood:

With 4 screws. Fig. 10.

1.

Mark mounting boreholes.
Dimensions can be found in Fig. 10
or use template.

2.

Drill 6 mm dia. holes and insert wall
plugs flush with the wall.

3.

Screw in the upper screws (on left and
right) until there is a gap of approx. 7
mm between the screw head and the
wall.

4.

Remove the filter grille
(see Instructions for use)

5.

Attach the extractor hood.

6.

If the cooker hood is not in perfect hori-
zontal level (fig. 11/1), adjust it by using
the adjusting screws (fig. 11/2).

7.

Tighten the lower screw (with washer)
inside the extractor hood. Fig. 12.

To a wall-hanging cupboard

60 cm 

wide extractor hood:

With 4 screws. Fig. 13.

90 cm 

wide extractor hood:

With 4 screws. Fig. 13.

1.

Dimensions for the mounting boreholes
can be found in Fig. 13, or place a tem-
plate on the base of the wall-
hanging cupboard.

2.

Mark the mounting holes and make pilot
holes with a bradawl. Fig. 13.
In exhaust-air mode (upwards) mark the
exhaust-air opening and saw out. 
Fig. 13.

Consider the location of the 
connection cable; if required, saw out
the cupboard.

3.

Remove the filter grille
(see Instructions for use).

4.

Screw the extractor hood to the base of
the cupboard. Fig. 14.

Final assembly

Extractor hood

Selecting the operating mode Fig. 15:

Exhaust-air mode:     Position 

1

Circulating-air mode: Position 

2

Connect to the power supply.

Insert the filter grille
(see Instructions for use).

56080 Int  10-01-2003  11:00  Pagina 9

Summary of Contents for LU13 series

Page 1: ...Operating Instructions Installation Instructions LU13 LU22 ...

Page 2: ......

Page 3: ...yed back into the kitchen The grease filter absorbs the grease particles in the kitchen vapours The activated carbon filter binds the odorous substances If the extractor hood is switched from exhaust air mode to circulating air mode the exhaust air opening must be sealed to prevent a hazardous situation see optional accessories in the Instructions for use Important information This extractor hood ...

Page 4: ...never be left unattended Do not flambé under the extractor hood Risk of grease filter catching fire catching fire from rising flames Certain restrictions apply if the extrac tor hood is to be installed over a fireplace which burns solid fuel coal wood etc see Installation instructions Always use gas hotplates correctly Important The flames of the gas hotplates must always be covered with a cooking...

Page 5: ...s of the filter grille Fig 1 1 2 Remove the filter grille Fig 1 2 3 Remove the wire grille and the saturated filter mat Fig 2 4 Clean the filter grille and insert a new filter mat Fig 2 5 Clamp the filter mat with the wire grille Fig 2 6 Re insert the filter grille Fig 1 2 The interlocks must lock into position on the left and right sides Fig 1 1 Metal grease filter The filter mats consist of non ...

Page 6: ... the filter grille Fig 1 1 2 Remove the filter grille Fig 1 2 3 Insert the activated carbon filter from below into the extractor hood housing and lock into position and turned clockwi se fig 3 4 Re insert the filter grille Fig 1 2 The interlocks must lock into position on the left and right sides Fig 1 1 Removing The activated carbon filter is removed in reverse sequence Replacing the activated ca...

Page 7: ...tainless steel cleaning agent Stainless steel surfaces Use a mild non abrasive stainless steel cleaning agent Clean only in the direction of the ground surface Do not clean stainless steel surfaces with scouring sponges or with cleaning agents containing sand soda acid or chlorides Replacing the lamps 1 Switch off the extractor hood and isolate the extractor hood by pulling out the mains plug or s...

Page 8: ...tinuous flow heaters water heaters ensure that the fireplace has an adequate air supply for combustion Before reading these instructions please fold out the illustrated back pages Important information Old appliances are not worthless rubbish Valuable raw materials can be reclaimed by recycling old appliances Before disposing of your old appliance render it unusable You received your new appliance...

Page 9: ...r mode with activated carbon filter there are no operating restrictions If the exhaust air is conveyed through the exterior wall a telescopic wall box should be used Fig 7 Connection options between the extractor hood and telescopic wall box Exhaust air hose or exhaust air pipe Direct connection Optimum performance of the extractor hood Short smooth exhaust air pipe Minimum number of pipe bends La...

Page 10: ...on cable must be replaced by the manufacturer or his customer service or a similarly qualified person If a permanent connection is required The extractor hood may be connected only by an electrical engineer who is registered at the relevant electricity supply company A disconnecting device must be fitted on the installation side Switches with a contact gap of more than 3 mm and all pole disconnect...

Page 11: ...erfect hori zontal level fig 11 1 adjust it by using the adjusting screws fig 11 2 7 Tighten the lower screw with washer inside the extractor hood Fig 12 To a wall hanging cupboard 60 cm wide extractor hood With 4 screws Fig 13 90 cm wide extractor hood With 4 screws Fig 13 1 Dimensions for the mounting boreholes can be found in Fig 13 or place a tem plate on the base of the wall hanging cupboard ...

Page 12: ...10 Notice ...

Page 13: ...11 Notice ...

Page 14: ...12 Notice ...

Page 15: ......

Page 16: ......

Page 17: ...Installation Instructions ...

Page 18: ......

Page 19: ......

Page 20: ...LIB0024982B Ed 07 15 BSH Ev Aletleri Sanayi ve Ticaret A Ş FSM Mah Balkan Cad 51 34771 Ümraniye İstanbul TURKEY www siemens home com ...

Reviews: