Web-based configuration
5.4 Web pages
LOGO! CIM
Operating Manual, 10/2021, A5E51250518-AA
53
Bind data
1.
Click "Add Row" to add a new row.
2.
Click the "Event Type" drop-down list to choose and event.
Event
Event
source
Source restriction
1
Changes from 1 to 0 Variable
Permitted data type: bool
2
Changes from 0 to 1
3
Value Changed
Permitted data type: all UDM permitted data type ex-
cept bool.
4
Greater than
Permitted data type: all UDM permitted data type ex-
cept bool.
Note
: The type and range of the reference value
should be the same as event source variable.
5
Equals
6
Less than
7
Receives message
Message
Any message
Note
The event "Greater than" is triggered on the rising edge, while "Less than" is triggered on
the falling edge.
No event triggered.
Event "Greater than 5" is triggered.
Event "Equals 5" is triggered.
Event "Less than 5" is triggered.
3.
Configure the event, it can be change of a variable (Page 49) or receive Messages (Page 50)
from a contact (Page 48).
If there is no variable or message meet your requirement in the list, you can add variable
or message on top of the list.